Kitchen anatomy
Kitchen anatomy, every part explained.
A fitted kitchen is more than cabinets. Choose a layer, then a part, to see what it is, why it matters and who is allowed to work on it.
98 parts in 10 layers
Start with a layer.
Each layer is a stage of the work. Choose one to see it in the drawing and to open its parts.
Layer 01 of 10
The room
The bare shell of the kitchen: outside and inside walls, the window and door openings, the floor structure and the ceiling. It is checked at the survey, and again once the old kitchen is stripped out and the walls and floor are bare.
- External wall The outside wall of the kitchen: usually a cavity wall, or solid brick in older homes
This is the wall between the kitchen and the outdoors. Homes built after the 1920s usually have a cavity wall: two skins of brick or block with a gap between them. Older homes are likely to have solid walls with no gap.
Why it matters
The cavity stops rain reaching the inner skin. Anything passed through it, such as a hood duct, a flue or an outside tap pipe, must not let water across. The wall type also decides which drill bits and wall plugs are used to hang units.
- Solid brick wall
- about 220 mm thick
- Cavity wall
- 270 to 300 mm thick
- Cavity gap
- about 50 mm
Good to know
- Measure the wall at a door or window. Solid brick is usually about 220 mm thick, a cavity wall 270 to 300 mm.
- Bricks showing only their long sides almost always mean a cavity wall. A regular mix of long and short ends points to solid.
- The cavity is about 50 mm wide and may be filled with insulation.
- Making a new opening, or widening one, for a window or door needs Building Regulations approval.
What we do We check the wall type at the free site survey and choose fixings to suit it. Any hole we make for a duct or pipe is sealed so rain cannot track through.
- Internal walls The walls inside the house: solid brick or block, or a stud frame covered in board
Internal walls are either solid masonry (brick or block) or stud partitions: a timber or metal frame covered in plasterboard. Some are load-bearing, which means they hold up floors, roof timbers or walls above.
Why it matters
The wall type decides how wall units are fixed. On a stud wall, timber or metal supports go in behind the board where units will hang, before it is boarded. Taking out a wall to make a kitchen diner is building work with its own rules.
- New beam resting on the wall each side
- normally at least 150 mm
- Fire protection for a steel beam
- normally 30 minutes
Good to know
- A structural engineer or surveyor can tell you whether a wall is load-bearing.
- Removing a load-bearing wall needs a Building Regulations application and an engineer's beam calculations before work starts.
- A wall that carries no weight may still need approval if it gives fire protection, for example between the kitchen and the stairs.
- Keep the completion certificate safe. You may need it to sell or remortgage.
What we do We check what each wall is built from at the survey and fix units to suit it. If you want a wall taken out, we flag that an engineer and Building Control come first.
- Lintel The beam over a window or door opening that carries the wall above
A lintel is the beam across the top of a window or door opening. It carries the weight of the wall above so the opening stays open. Lintels may be steel, concrete or timber.
Why it matters
Kitchen plans sometimes widen a window or add a door to the garden. Every new or wider opening needs a lintel sized for its width and the load above. That is controlled building work.
- Lintel resting on the wall each side
- at least 150 mm
- On openings up to 1,200 mm wide
- at least 100 mm
Good to know
- A new or wider opening needs its own Building Regulations application, even if a registered installer fits the window.
- The beam or lintel is designed for its position, the width of the opening and the load it carries.
- Building Control, or a registered building control approver, checks the beam, the walls or padstones it rests on, and its fire protection.
- Lintel ends normally rest at least 150 mm on the wall each side, or 100 mm on spans up to 1,200 mm.
What we do If your plan needs a new or wider opening, we flag it at the free site survey. That way the engineer's design and Building Control approval are in place before work starts.
- Window The glazed window in the outside wall, which brings in daylight and fresh air
The kitchen window is a glazed frame set into the outside wall. It brings in daylight and, when opened, fresh air.
Why it matters
Kitchens need extra ventilation, normally from an extractor fan as well as a window. Replacing a window is controlled building work in England. It must be done by a registered installer or checked by Building Control.
- Rules for replacement windows since
- 1 April 2002
- Certificate due
- within 8 weeks of completion
- Safety glazing zone in windows
- up to 800 mm above the floor
Good to know
- Building Regulations have covered replacement windows since 1 April 2002.
- A registered installer must give you a certificate within 8 weeks. Solicitors look for it when you sell.
- Replacing only a failed double-glazed unit or a broken pane is not covered by the regulations.
- Glass less than 800 mm above the floor must be safety glass, be in small panes or be guarded.
What we do Where the kitchen has a window, we measure it and its sill at the free site survey and plan the worktop, sink and wall units around them.
- Back door Not in this drawing An outside door from the kitchen, often to the garden, with a threshold at the bottom
The back door is an external door, often leading from the kitchen to the garden. The threshold is the strip across the bottom of the opening that you step over.
Why it matters
The rules on replacing it depend on how much of it is glass. New flooring raises the floor, so the finished height has to meet the threshold neatly.
- Safety glazing zone in doors
- up to 1,500 mm above the floor
- Replacement needs no approval if
- less than half of the door is glazed
Good to know
- A replacement door that is less than half glazed does not need approval. Otherwise it follows the same routes as a window.
- Glass in a door, up to 1,500 mm above the floor, must be safety glass or be protected.
- Adding a level, step-free threshold where there was none needs approval and careful detailing to keep damp out.
- New flooring adds about 5 mm (thin vinyl) to 20 mm or more (tiles on adhesive) to the floor height.
What we do Where the kitchen has a back door, we check the floor level there during the free site survey, so the new floor can finish neatly at the threshold.
- Subfloor The structural floor under everything: a concrete slab or timber boards on joists
The subfloor is the structural floor that everything else sits on. A ground floor is either a solid concrete slab laid on hardcore, or a suspended timber floor: boards on joists over an air space.
Why it matters
Units, worktops and appliances are heavy. A concrete floor may take the extra load without trouble. A timber floor can feel bouncy, so its joists and boards need checking first.
- Concrete slab
- at least 100 mm thick
- Air space under a timber floor
- at least 150 mm
- Board under a washing machine on timber
- at least 30 mm thick
Good to know
- Timber floors are best checked and repaired while the room is empty, before the units go in.
- Timber blocking fitted between joists stiffens the floor and can reduce tile cracking from washing machine vibration.
- On a wooden floor, one appliance maker advises standing a washing machine on a screwed-down, water-resistant board at least 30 mm thick.
- Renewing the screed of a concrete floor, or replacing boards or joists, can need a Building Regulations application.
What we do We check the floor type at the survey and again once the old kitchen is out. If we find weak boards or joists, they can be put right before any units go in.
- Ceiling Not in this drawing Usually plasterboard fixed under the joists; lath and plaster in older homes
Modern ceilings are plasterboard sheets fixed to the underside of the joists above, then skimmed. Older homes often have lath and plaster: thin timber strips covered in coats of lime plaster.
Why it matters
A kitchen ceiling takes steam from cooking and holds the lights. In a flat it is also part of the fire barrier between your home and the one above.
- Board on joists up to 450 mm apart
- 12.5 or 15 mm
- Fire resistance between flats
- 30 to 60 minutes in most low-rise blocks
- Replacement that brings in the rules
- more than 25% of the ceiling
Good to know
- A recessed downlight can give far less fire protection than the board it replaces. Between flats, downlights must be fire protected.
- Replacing more than a quarter of a ceiling under a cold loft or flat roof normally brings in Building Regulations and better insulation.
- Old lath and plaster ceilings are heavy and can sag or fall if disturbed, so they are assessed before work starts.
- Textured ceiling coatings in homes built or refurbished before 2000 may contain asbestos. Do not drill, sand or scrape them.
What we do We can replace a damaged or uneven kitchen ceiling. Downlight positions and fire-protected fittings are then planned with a registered electrician we partner with.
- Chimney breast Not in this drawing The part of an old chimney that juts out into the room
A chimney breast is the part of a chimney that projects into a room, around the flue.
Why it matters
It is load-bearing, so removing it is structural work. It needs Building Regulations approval and an engineer's design for supporting what stays above.
- Party wall notice
- at least 2 months before work
- Neighbour's time to reply
- 14 days
Good to know
- The engineer chooses the support, such as a fire-protected steel beam or brackets.
- On a wall shared with a neighbour, a party wall notice must be served first, in England and Wales.
- Gas, water and electrics in the chimney breast must be cut off first by a qualified professional.
- A full plans application may suit better, because the calculations must be approved before work begins.
What we do Where a chimney breast stays, we plan the units around it. If you want it removed, we flag at the survey that an engineer, Building Control and possibly a party wall notice come first.
- Air bricks Not in this drawing Vented bricks in the outside wall that let air flow under a timber floor
Air bricks are bricks with holes or a grille, set in the outside walls of homes with suspended timber floors. They let air flow through the space under the floor.
Why it matters
Moving air keeps the floor timbers dry. Without it, damp air builds up under the floor and wet rot can spread, often at joist ends near damp walls.
- Vent area
- at least 1,500 mm² per metre of wall, or 500 mm² per m² of floor
- Air space under the floor
- at least 150 mm
Good to know
- They are needed in two opposite outside walls, so air can cross under every part of the floor.
- Nothing added under or around the floor, such as new insulation, should block them.
- Their grilles keep vermin out but should not hold back the airflow.
- Signs of rot include floor timber that has gone soft, cracked, darkened or warped.
What we do When we survey a timber floor, we check whether the air bricks are clear, and plan any new floor work or insulation so it does not block them.
- Outside drain and soil stack Not in this drawing Where kitchen waste water leaves the house: an outside gully or the soil stack
Waste water from the sink, dishwasher and washing machine leaves through a drain gully or the soil stack. A gully is a drain opening at ground level with a grating and a water seal. The soil stack is the main upright drain pipe.
Why it matters
Waste pipes need a steady fall to drain, so the distance to the gully or stack limits where the sink can go. Drains must keep their fall, so moving a sink is not always possible.
- Sink waste run without venting
- up to 3 m (40 mm pipe) or 4 m (50 mm pipe)
- Fall
- 18 to 90 mm per metre
- Sink trap water seal
- 75 mm
Good to know
- Without extra venting, a sink waste can run 3 m to the stack in 40 mm pipe, or 4 m in 50 mm pipe.
- The waste pipe needs a fall of 18 to 90 mm for every metre.
- Appliance waste must go to the foul drain. If it runs to a rainwater drain, the current owner must put it right.
- Moving the sink or adding a new waste connection may need Building Regulations approval before work starts.
What we do At the free site survey we plan the sink around the existing waste route. Our plumbing connects appliance wastes to the foul drain.
- Asbestos in older kitchens Not in this drawing A banned material that may still be in homes built or refurbished before 2000
Asbestos was widely used in building materials until it was banned in 1999. Homes built or refurbished before 2000 may still contain it.
Why it matters
Material in good condition that will not be disturbed is often best left alone. A kitchen refit drills, cuts and lifts old surfaces, so suspect material has to be checked before work starts. By law, the firm doing the work must check whether asbestos is present, or assume it is.
- Homes that may contain it
- built or refurbished before 2000
- Banned in buildings
- 1999
Good to know
- In kitchens, look at textured ceiling coatings, old vinyl or thermoplastic floor tiles and their adhesive, boiler cupboard boards and cement flue pipes.
- Tell your fitter about any suspect material before work starts. Never put it in household waste.
- Some small jobs can be done by trained workers. Pipe lagging, sprayed coatings and most insulating board removal need a licensed contractor.
- Where work will break into walls, floors or ceilings, a refurbishment survey may be needed first.
What we do We ask about the age of your home at the survey. If suspect material turns up during a fit, we stop work until it has been tested and dealt with properly.
Layer 02 of 10
Water and drains
Everything that brings mains water in and takes used water away, from the stop tap and meter to the sink waste and outside tap. In a refit this work comes first, because the units and worktop then hide the pipes.
- Mains water supply The pipe that brings drinking water from the main in the street into your home
Mains water reaches your home through a supply pipe from the water main in the street. It usually comes up indoors under the kitchen sink, at the main stop tap. The pipe that carries it on through the house is often called the rising main.
Why it matters
The water company looks after the main and the pipe up to your property boundary. From the boundary inwards, the supply pipe and all your indoor plumbing are yours to maintain and repair. Homes built before 1970 may still have a lead supply pipe.
- Minimum pressure the water company must keep
- 0.7 bar (7 m head)
- Lead pipes possible in homes built
- Before 1970
- Legal limit for lead in drinking water
- 10 micrograms per litre
Good to know
- A supply pipe shared by several homes, common in terraces, is the joint responsibility of every owner it serves.
- Lead pipe is dull grey and soft. A gentle scrape with a coin shows shiny silver metal.
- Until a lead pipe is replaced, run the cold tap before drinking if the water has stood in the pipes for hours.
- The water company must keep at least 0.7 bar of pressure at your outside stop valve. Pressure inside your own pipes is your responsibility.
What we do At the survey we look for where your water comes in and, where we can see it, check what the pipe is made of. If we find lead, we tell you before the new kitchen covers it.
- Main stop tap The tap that turns off all the water to your home, also called the stopcock
The main stop tap (stopcock) is a valve on the incoming mains pipe that shuts off water to the whole home. It is usually under the kitchen sink. It can also be in a kitchen cupboard, utility room, downstairs toilet, garage, cellar or under the stairs.
Why it matters
If a pipe bursts, this is how you stop the water quickly. The water regulations require every home to have a conveniently placed stop valve. Fittings you need to operate must not be hidden where they are hard to reach, so it must stay reachable inside a unit.
- To close
- Turn clockwise
- How often to check it
- Every 6 months
- After opening fully, turn back
- Half a turn
Good to know
- Turn it clockwise to close, slowly and without forcing. Open the kitchen cold tap: the flow should stop within a few seconds.
- Check it every six months by turning it off and on again. Then turn it back half a turn so it does not seize.
- If it is stiff or does not stop the water, do not force it. Ask a plumber to look at it.
- There is often a second stop valve outside, under a small cover near your boundary. It belongs to the water company.
What we do At the survey we look for your stop tap and, where we can reach it, check that it works. When we fit the sink unit, we keep the stop tap within easy reach and do not close it in behind a fixed panel.
- Water meter Measures the water you use; often inside a kitchen cabinet next to the stop tap
A water meter records how much water your home uses. In the North West the water company normally fits it indoors on the incoming pipe, often under the kitchen sink beside the stop tap. Otherwise it goes outside, under a small lid in the footpath, in a garden box or in a wall box.
Why it matters
The meter belongs to the water company, not to you. It is a criminal offence to tamper with it, or to do work that means disconnecting it, without the company's consent. It must stay easy to reach and read, so it should never be fully boxed in.
- Typical household meter
- About 100 mm wide by 150 mm high
- Usually read
- About every 6 months
Good to know
- Keep the meter face visible and leave enough space around it for it to be replaced.
- An indoor meter can sit in a kitchen, utility room or garage, as long as it comes after the stop tap.
- Any move needs the water company's permission first. Moves to or from outside are done only by the water company.
- An earth bonding cable fitted across an indoor meter must stay in place.
What we do We plan the sink base or cabinet around the meter, keeping its face visible and leaving room to replace it. If the meter is in the way, we ask you to contact your water company before any work starts.
- Hot and cold pipework The copper or plastic pipes that carry hot and cold water to the sink and appliances
Hot and cold water reach the kitchen through copper or plastic pipe. Taps and appliances are usually fed in 15 mm pipe, with 22 mm for main runs and boiler connections. Plastic push-fit pipe comes in the same sizes and bends to fit tight spaces.
Why it matters
Base units have an empty gap behind the back panel, called the service void, where pipes run out of sight. Pipes must fit in that gap or be moved before the units go in. No water fitting may be buried in a wall or solid floor, and joints must stay reachable.
- Pipe to taps and appliances
- 15 mm
- Main runs and boiler connections
- 22 mm
- Service void in a base unit
- About 42 mm (varies by maker)
Good to know
- The service void is often about 42 mm deep in base units but about 17 mm in wall units, varying by maker.
- Pipe has been metric since the early 1970s, so older imperial pipe needs adaptors to join new pipe.
- Thin 8 to 10 mm pipe is mainly used for heating, but it can feed a mixer tap.
- Moving the sink usually means moving the hot and cold feeds as well as the waste.
What we do Where the new layout needs it, our plumbers reroute the hot and cold pipes before the units go in. We keep joints and valves where they can be reached later.
- Isolating valves Small valves that shut off one tap or appliance without turning off the whole house
An isolating valve, also called a servicing valve, is a small valve on the pipe feeding one tap or appliance. Closing it shuts off that one item while the rest of the house keeps its water.
Why it matters
The water regulations require enough servicing valves for fittings to be repaired or replaced with little water lost. A leaking tap or dishwasher can then be dealt with without turning off the main stop tap.
Good to know
- Official guidance is to fit them as close as practical to the tap or appliance they serve.
- The same guidance says to label them, so you know which valve controls what.
- They sit inside the cabinets, so they must stay reachable and not be hidden behind fixed panels.
- Ask your fitter to show you where each valve is when the kitchen is finished.
What we do When we plumb the kitchen, we can fit an isolating valve on each feed to the taps, dishwasher and washing machine, and leave them reachable inside the units.
- Sink waste and trap The trap and pipe that carry used water from the sink to the drain
Under the sink is a trap, a bend that holds water to stop drain smells coming up. From the trap, a waste pipe runs to a drain gully outside or into the soil stack (the main drain pipe).
Why it matters
Waste water only flows if the pipe slopes, so the waste run limits where a sink can go. For a 40 mm sink waste, the guidance allows up to 3 m, falling 18 to 90 mm per metre. Longer runs need extra venting, such as an air admittance valve.
- Sink trap
- 40 mm, with a 75 mm water seal
- Longest unvented 40 mm sink waste
- 3 m
- Fall
- 18 to 90 mm per metre
Good to know
- A kitchen sink needs a trap at least 40 mm across, holding a 75 mm water seal.
- Traps should come apart or have a cleaning eye, so blockages can be cleared.
- Sink and appliance wastes must go to the foul drain, never a rainwater drain. Putting a wrong connection right is the owner's legal responsibility.
- Moving a sink to a new connection on a soil stack or underground drain usually needs building regulations approval.
What we do We plan the sink position around the waste run and the fall it needs. We connect wastes to the foul drain and leave the trap where it can be taken apart.
- Washing machine and dishwasher connections The cold water valve and waste connection behind a washing machine or dishwasher
A washing machine or dishwasher needs a cold water feed with its own valve, and a way to drain. The drain hose clips onto a spigot, a short outlet on the sink trap. Or it hangs into a standpipe, an upright waste pipe with its own trap.
Why it matters
A badly set drain hose can siphon water out of the machine during a wash. A wrongly plumbed appliance can push the water out of the sink trap and let drain smells in. Washing machines are the appliance most often plumbed into the wrong drain.
- Appliance trap
- 40 mm, with a 75 mm water seal
- Drain hose high point
- Typically 40 to 100 cm above the floor
- Hose insertion into a standpipe
- No more than 15 cm
Good to know
- The drain hose usually has to rise to between 40 and 100 cm above the floor. The machine's manual gives the exact height.
- Push the hose no more than 15 cm into a standpipe, or it can siphon.
- A built-in dishwasher's hoses and plug should reach at least 60 cm, so it can be pulled out without disconnecting.
- Not every appliance has built-in backflow protection. One without it needs its own protection device on the feed.
What we do We fit the feed valves and waste connections in the next cabinet, where you can reach them. We check which drain each waste runs to before we connect it.
- Outside tap A garden tap on the outside wall, fed through the wall from the cold mains pipe indoors
An outside tap is a tap on the outside wall for a garden hose. It is fed by a branch off the cold mains pipe indoors, which passes through the wall. It usually has its own isolating valve indoors, so it can be shut off for winter.
Why it matters
A hose left in a bucket, pond or drain can draw dirty water back into your drinking supply. So an outside tap needs a double check valve, which only lets water flow one way. Where the tap was fitted since 1 July 1999, that valve must be indoors and protected from frost.
- Backflow protection
- Double check valve
- Valve must be indoors in homes built after
- 1 July 1999
- Replace the check valve
- About every 10 years
Good to know
- An ordinary outside tap does not need to be notified to the water company, but it must still meet the water rules.
- Taps with a check valve built into the tap are only lawful if they were fitted before 1 July 1999.
- Before winter, close the indoor valve, drain the tap, store the hose and fit an insulated cover.
- Check valves should be replaced about every 10 years.
What we do Our plumbers can fit an outside tap, with a double check valve and an isolating valve indoors, where frost cannot reach them.
- Water softener Not in this drawing A unit that removes the minerals that cause limescale
A water softener swaps the calcium and magnesium that make water hard for sodium. That cuts limescale and helps soap lather. It is fitted on the mains pipe just after the stop tap.
Why it matters
Most water in the North West comes from upland reservoirs and is soft or very soft. The Manchester area sits in the soft to moderately soft bands. Check your postcode with your water company before paying for a softener.
- Soft water
- 0 to 50 mg per litre
- Manchester area (regulator's map)
- Roughly 0 to 100 mg per litre
- Scale starts to form from
- About 200 mg per litre
Good to know
- Keep one unsoftened kitchen tap for drinking and cooking. Never use softened water for baby feeds.
- It needs floor space for salt refills, a drain with an air gap, an overflow to outside and a socket.
- A softener that uses water to regenerate must be notified to the water company before it is fitted.
- It needs regular salt top-ups and maintenance.
What we do Our plumbers can fit a softener with a separate unsoftened drinking tap. At the survey we help you check whether your water is hard enough to need one.
Layer 03 of 10
Gas and heating
The gas meter and pipes, the boiler and flue, the pipes and heaters that warm the room, and the carbon monoxide alarm. In a refit, clashing pipes and radiators move before the units go in, and a Gas Safe registered engineer does the gas work.
- Gas meter Measures the gas you use; often in the kitchen, under the stairs or in an outside box
The gas meter records the gas your home uses. It may be indoors, often in the kitchen or under the stairs, or outside in a box on the wall. Beside it is the emergency control valve, a lever that turns off all the gas.
Why it matters
The gas network owns the pipe up to the emergency control valve, and your gas supplier is responsible for the meter. Moving a meter yourself is illegal. The meter and valve must stay readily accessible, so units built round them must leave them easy to reach.
- To turn off
- A quarter turn (90 degrees) of the lever
- Gas emergency line
- 0800 111 999, free, 24 hours
- Space for a typical outside meter box
- About 550 by 550 by 300 mm
Good to know
- The lever is on when it lines up with the pipe. A quarter turn either way shuts off the gas.
- If you smell gas, call the National Gas Emergency Service free on 0800 111 999, at any hour.
- Nothing that burns easily may be stored in a meter box.
- Homes built before the 1970s often have the meter indoors. Newer standards prefer it outside.
What we do Where the gas meter is in the kitchen, we design the units so the meter and its emergency control valve stay easy to see and reach. If the meter needs to move, we ask you to contact your gas supplier first, as it is their job.
- Gas pipework The pipe that carries gas from the meter to the boiler and hob
Gas pipework runs from the meter to each gas appliance, such as the boiler and hob. It is sized so every appliance can run at full rate at once. A typical modern boiler takes a 22 mm gas connection.
Why it matters
Anyone paid to work on gas pipes must be Gas Safe registered, and the law treats DIY gas jobs as gas work too. Gas from a damaged or enclosed pipe can collect unseen in voids. After any work, the engineer must test the pipework for leaks before it is used.
- Typical boiler gas connection
- 22 mm
- Gap from a consumer unit or electricity meter
- At least 150 mm
- Gap from sockets, switches and cables
- At least 25 mm
Good to know
- Gas pipe must not run inside a cavity wall. It may only cross the wall by the shortest route, in a sealed sleeve.
- It must not run in an unventilated void, shaft or duct.
- It should stay at least 150 mm from a consumer unit or electricity meter, and 25 mm from sockets and cables.
- Every Gas Safe engineer carries an ID card. The back lists the work they are qualified to do.
What we do A Gas Safe registered engineer we partner with moves and connects gas pipework and tests it for leaks. Nobody on our own team works on gas.
- Boiler in a kitchen unit The gas boiler that heats your radiators and water, often hidden in a kitchen unit
A combi boiler heats water straight from the mains, so it needs no hot water cylinder or loft tanks. A system boiler feeds a separate hot water cylinder but needs no loft tanks. A regular boiler needs a cylinder and tanks in the loft.
Why it matters
A boiler inside a tall larder unit or a deep wall unit must keep the clear space its maker asks for. An engineer has to reach it for every service and repair. Boiler cover and guarantees can be refused where a boiler is built over.
- Clear space in front
- About 600 mm (check the boiler's manual)
- Boiler housing wall unit (one supplier)
- About 600 mm wide by 460 mm deep
- Notification after fitting
- Within 30 days
Good to know
- Makers typically ask for about 600 mm of clear space in front, so an engineer can stand and work.
- Side gaps can be as small as 2.5 to 5 mm, but the door or panel in front must come off.
- A modern room-sealed boiler usually needs no vents in its cupboard, but the cupboard must not be used for storage.
- The installer must notify building control within 30 days. You then receive a compliance certificate by post.
What we do Where the boiler is in the kitchen, we build its housing unit to the clearances in the boiler's manual, with a removable front for servicing. Any work on the boiler itself is done by our Gas Safe registered partner engineer.
- Boiler flue The pipe that takes the boiler's waste gases outside, through the wall or roof
The flue carries the boiler's waste gases to the outside air. A modern boiler has a balanced flue, which takes fresh air in and lets waste gases out at the same point. It usually runs straight through the outside wall behind the boiler, or up through the roof.
Why it matters
Building work must not block, enclose or damage a flue. Where a flue is hidden in a ceiling or boxing, hatches are needed so an engineer can check its whole length. Without them, an engineer will class the boiler as at risk and, with your permission, turn it off.
- Inspection hatch
- At least 300 by 300 mm
- Furthest flue joint from a hatch
- 1.5 m
- Flue end from opening windows and doors
- At least 300 mm
Good to know
- Hatches should be at least 300 mm square, with no flue joint more than 1.5 m from a hatch.
- The flue end outside should be at least 300 mm from any opening window, door or air vent.
- A new window or door near an existing flue must keep the required distance.
- A plume of water vapour is normal, but it can annoy neighbours, so the position matters.
What we do If a flue runs through boxing or a ceiling we are changing, we fit inspection hatches where the gas engineer specifies, so the flue can still be checked.
- Condensate pipe The small plastic pipe that drains water from a condensing boiler
A condensing boiler produces water, called condensate, as it runs. A plastic pipe carries this water from the bottom of the boiler to a drain.
Why it matters
The preferred route is indoors, into a soil stack or a sink or appliance waste, where it cannot freeze. Most frozen condensate breakdowns happen where part of the pipe runs outside without proper insulation.
- Indoor pipe
- At least 19 mm inside (typically 22 mm pipe)
- Fall away from the boiler
- At least 45 mm per metre
- Longest outside run
- 3 m, at least 30 mm inside, insulated
Good to know
- Indoors the pipe should be at least 19 mm across inside and fall at least 45 mm per metre.
- An outside run should be wider, at least 30 mm inside, no longer than 3 m, and insulated.
- If it freezes, warm the most exposed part with a hot water bottle or warm water, never boiling water.
- After thawing, the boiler usually needs resetting.
What we do When we fit a new sink waste, we can connect the condensate pipe to it indoors. We keep its fall and route clear of the new units.
- Central heating pipes The flow and return pipes that carry hot water between the boiler and radiators
Every radiator sits between a flow pipe bringing hot water from the boiler and a return pipe taking cooler water back. Most radiators are fed in 15 mm pipe, branching off 22 mm main runs. Some homes have thinner microbore pipe, under 15 mm.
Why it matters
When a radiator moves for new units, its pipes have to move too. The system is drained, the pipes are rerouted, then it is refilled, bled and dosed with corrosion inhibitor. Pipe size also limits how much heat each radiator can get.
- Pipe to most radiators
- 15 mm
- Main runs
- 22 mm (sometimes 28 mm)
- Microbore
- 6, 8, 10 or 12 mm
Good to know
- Microbore pipe (6 to 12 mm) restricts flow and is easily kinked or knocked.
- New heating pipes in voids outside the heated rooms should be insulated.
- Heat pumps move water much faster than boilers, so ask whether your pipes would cope if you might switch later.
- After rerouting, each radiator is rebalanced at its lockshield valve.
What we do Where heating pipes need to move for the new layout, our plumbers drain the system, reroute them, then refill, bleed and rebalance it. New pipes that run through voids are insulated.
- Radiator The panel on the wall that heats the room with hot water from the boiler
A radiator heats a room with hot water from the boiler, mainly by warming the air that moves over it. Panel radiators are named by type: Type 11 has one panel and one row of fins, Type 22 has two of each. Vertical radiators are tall and narrow, for rooms with little free wall.
Why it matters
A radiator needs air moving freely over it, so it cannot be boxed in behind units. A radiator on a wall that is getting new units usually has to move or be replaced by another heater. Swapping to a vertical radiator usually means changing the pipework.
- Keep furniture away by
- At least 20 cm
- Vertical radiators (one range)
- 300 to 750 mm wide, 1,800 to 2,100 mm tall
- TRV setting 3
- About 20 °C
Good to know
- A thermostatic radiator valve (TRV) senses the room and controls the flow. Setting 3 is about 20 °C.
- The other valve, the lockshield, sits under a plain cap. The installer sets it to balance the system.
- When a boiler is replaced, radiators outside the thermostat's room should have a TRV, but not in that room.
- Keep furniture and cabinets at least 20 cm away. Even a decorative grille cuts output by a few per cent.
What we do We plan with you where the radiator can go, or whether a vertical radiator or plinth heater suits better. Our plumbers can move it and rebalance the system.
- Plinth heater A slim fan heater hidden in the plinth under a base unit, also called a kickspace heater
A plinth heater, also called a kickboard or kickspace heater, sits in the space under a base unit. A small fan blows room air across a heater and out through a grille in the plinth. Plumbed models use central heating water, electric models have their own element, and dual models have both.
Why it matters
It frees up wall space when a radiator has to make way for units. A plumbed model starts its fan once the heating water is warm, so it comes on and off with the heating like a radiator.
- Minimum plinth height
- 120 mm (80 mm slimline)
- Output, mid-size plumbed model
- About 1.3 kW at 80 °C, 0.8 kW at 55 °C
- Electric models
- 0.6 to 3 kW
Good to know
- It needs a plinth at least 120 mm high, or 80 mm for a slimline model.
- A plumbed model needs 15 mm flow and return pipes with isolating valves, plus a fused spur for the fan.
- Its output drops at low water temperatures, so check the size if you have or plan a heat pump.
- Keep the grille clear of mats, bins and pet beds. The fan is quiet but you can hear it.
What we do We can fit a plinth heater, with flexible hoses and isolating valves so it can be serviced, and cut the plinth to suit. The fan's electrical supply is connected by our registered electrician partner.
- Underfloor heating Heating pipes or electric mats laid under the floor instead of radiators
Wet underfloor heating pumps warm water through loops of plastic pipe, often set in screed (a smooth layer laid over the floor base). Electric underfloor heating uses thin heating wires, often on mats under tiles. Electric is easier to fit in one room but costs more to run.
Why it matters
Floor height is the main limit when adding it to an existing kitchen. Heat is not wanted under fixed units, so pipes and mats go in the open floor only. Screed and tile adhesive must be fully dry before the heating goes on.
- Low-profile wet system
- Adds about 15 to 22 mm
- Minimum screed over pipes
- typically 65 mm hand-mixed, 50 mm liquid (check the maker's instructions)
- Electric mat output
- 150 or 200 W per square metre
Good to know
- Low-profile wet systems laid over an existing floor add about 15 to 22 mm. Systems in screed add far more.
- Pipes in screed take one to three hours to warm up. Thin systems warm up much faster.
- After tiling over an electric mat, wait at least 7 to 10 days before switching it on.
- Electric mats need RCD protection and a floor sensor. The maker asks for a registered electrician to connect them.
What we do Where there is underfloor heating, we plan the heated area around the units and lay the floor finish once the screed or adhesive is ready. Electrical connections are made by a registered electrician we partner with.
- Thermostat and controls The room thermostat and timer that tell the heating when to run and how warm to get
A timer switches the heating on and off at set times, and a programmer allows different times on different days. A room thermostat sets the temperature you want. A programmable thermostat does both jobs.
Why it matters
The room with the thermostat decides when the heating switches off for the whole house. A kitchen is warmed by the oven, hob and appliances. A thermostat there would tend to switch the heating off while other rooms are still cold.
- Suggested room temperature
- 18 to 21 °C
- Saving from turning it down 1 °C
- About 10%
Good to know
- Site it with free air around it, away from heat sources, sunlight, curtains and furniture.
- Advice on the best room varies: a hall, a landing or the main living room.
- Do not fit a thermostatic radiator valve in the same room as the thermostat.
- A replacement gas boiler must come with a timer and room thermostat. A replacement combi also needs one extra energy-saving measure.
What we do At the survey we check where your thermostat is. If it is in the kitchen, we can move it to a better place while the walls are open.
- Carbon monoxide alarm A small alarm that warns of carbon monoxide from a boiler or other fuel-burning appliance
A carbon monoxide (CO) alarm sounds a warning when it detects carbon monoxide gas. It goes on the ceiling or high on a wall, 1 to 3 m from the appliance.
Why it matters
When a new or replacement gas boiler is fitted, building regulations guidance calls for a CO alarm in the same room. Gas cookers and hobs are left out of this rule. An alarm is no substitute for correct installation and regular servicing.
- Distance from the appliance
- 1 to 3 m
- From walls, if on the ceiling
- At least 300 mm
- Below the ceiling, if on a wall
- At least 150 mm
Good to know
- Ceiling: at least 300 mm from walls. Wall: as high as possible, but not within 150 mm of the ceiling.
- Landlords in England must fit one in any room with a fixed fuel-burning appliance, gas cookers excepted.
- Look for one marked BS EN 50291-1 with a battery that lasts its working life. Test it monthly.
- In Scotland, every home needs one in any room with a boiler, open fire or wood burner.
What we do If your boiler is in the kitchen, we plan a place for the CO alarm, clear of the new wall units.
Layer 04 of 10
Power and light
Everything electrical in the kitchen: the consumer unit, hidden cables, sockets, switches, lights and the heat alarm. In a refit the existing earthing and bonding are checked first, because the safety of the new work depends on them.
- Consumer unit and electricity meter The fuse box that splits your supply into circuits, beside the electricity meter
The consumer unit (the modern fuse box) splits the incoming supply into circuits, each with its own breaker. Its RCDs (residual current devices) cut the power fast if current leaks to earth, which protects you from shocks. The meter beside it belongs to your energy supplier, and the sealed main fuse belongs to the network operator.
Why it matters
Every new kitchen circuit starts here, so the board needs space and the right protection. An older board does not have to be replaced just because the rules changed, only when it cannot safely take the new work. Replacing a consumer unit is notifiable building work in England.
- RCD test button
- Press every 6 months
- Consumer unit switches, accessible new homes
- 1,350 to 1,450 mm above floor
- Typical maximum cable from meter to unit
- 2 to 3 m
Good to know
- A new or replacement unit must have a non-combustible case, usually steel, or sit inside a non-combustible cabinet.
- Circuits split across several RCDs, or an RCBO (breaker and RCD in one) on each, mean one fault does not cut everything.
- It must stay easy to reach for switching off and testing. Guidance says not to fit one directly above or beside a sink.
- Network operators usually accept only 2 to 3 m of cable between the meter and the unit, which limits how far it can move.
What we do We look at the consumer unit and meter at the free site survey. Any board change or new circuit is done and certified by a registered electrician we partner with.
- Earth bonding Green and yellow cables that link metal water and gas pipes to the home's earth
Main bonding is a green and yellow cable clamped to metal water and gas pipes near where they enter the home. It links them to the main earth. This reduces the risk of a shock to anyone touching two separate metal parts during a fault.
Why it matters
Whenever electrical work is done, the electrician must check that the earthing and bonding are up to standard. The safety of the new work depends on them. That is why a kitchen quote can include bonding work away from the new units.
- Clamp distance from point of entry or gas meter
- Within 600 mm
Good to know
- On gas, the clamp goes on the rigid pipe on the house side of the meter, within 600 mm of it where practical.
- On water, it goes as close as practical to where the pipe enters the building.
- A service that comes in as plastic pipe generally does not need bonding.
- An older 6 mm² bond need not be upgraded to 10 mm² if it connects everything it should and shows no heat damage.
What we do Our registered electrician partner checks the earthing and bonding before any new electrical work. If an upgrade is needed, it is shown in your written estimate.
- Circuits and cables Hidden cables that carry power from the consumer unit to each socket, switch and light
Each circuit is a cable run from its own breaker in the consumer unit. Sockets are wired as a ring (a loop with both ends on one breaker) or a radial (a single run to the last point).
Why it matters
Buried cables are easy to hit when drilling for wall units, shelves or rails. Rules on where cables run, and how deep walls may be cut, keep both the wiring and the wall safe.
- Cable zone from top of wall or corner
- 150 mm
- Buried cables that need RCD protection
- Less than 50 mm deep
- Maximum chase depth
- Vertical 1/3, horizontal 1/6 of the wall or leaf
Good to know
- Hidden cables normally run straight up, down or across from a switch or socket, or within 150 mm of a ceiling or corner.
- Cables buried less than 50 mm deep need 30 mA RCD protection, unless they have a metal covering or similar protection.
- A chase (a groove cut for a cable) should be no deeper than a third of the wall if vertical, a sixth if horizontal.
- A new circuit is notifiable in England. Extra sockets on an existing kitchen circuit are not, but they are still tested and certified.
What we do We plan cable routes for new sockets, switches and lights with you at the survey. New circuits are run, tested and certified by a registered electrician we partner with.
- Sockets The 13 A sockets above the worktop and behind built-in appliances
Kitchen sockets are the 13 A outlets above the worktop, plus those behind or beside appliances. Every new or added socket needs 30 mA RCD protection, at the consumer unit or built into the socket. The wiring regulations set no fixed distance from a sink, so the gaps quoted below are good practice.
Why it matters
A kitchen runs many plug-in appliances, and adding sockets is safer than relying on adaptors. Sockets also need sensible positions away from water and heat.
- RCD protection for new sockets
- 30 mA
- Good-practice gap from sink bowl
- At least 300 mm
- Good-practice gap from hob edge
- At least 100 mm
Good to know
- England sets no minimum number. Scotland asks for at least 6 in a kitchen, 3 above the worktop, plus appliance outlets.
- Good practice is at least 300 mm sideways from the sink bowl and 100 mm from the hob edge, never directly above a hob.
- A socket in the sink cupboard is acceptable if a leaking valve or hose is unlikely to reach it.
- In England, adding a socket to an existing kitchen circuit is not usually notifiable; the rules in Wales differ, so check before work starts.
What we do We agree socket positions with you at the survey, around your appliances and worktop layout. Our registered electrician partner fits, tests and certifies them.
- Cooker circuit and switch A dedicated circuit for the oven and hob, with its own control switch
Higher-powered ovens, hobs and cookers are wired straight to their own circuit from the consumer unit. A cooker control switch on that circuit lets the appliance be isolated for maintenance.
Why it matters
A 13 A plug can supply up to about 3 kW, so bigger hobs and cookers need their own circuit. Guidance suggests one for any cooking appliance over 2 kW. A new cooker circuit is notifiable work in England, but connecting to an existing one is not.
- Own circuit suggested for cooking appliances over
- 2 kW
- The most a 13 A plug can supply
- About 3 kW
- Switch gap from hob edge
- At least 100 mm
Good to know
- Many single ovens come with a 13 A plug. One under 3 kW can run from the socket circuit if it is not overloaded.
- The cooker switch must stay easy to reach, but it can sit inside a neighbouring cupboard.
- It does not need to be lockable, and it should not sit directly above the hob or oven.
- Switches at least 100 mm sideways from the hob edge are regarded as likely to comply.
What we do We check your oven and hob ratings against the existing circuit at the survey. Any new cooker circuit is installed and certified by a registered electrician we partner with.
- Appliance switches Switches above the worktop that turn off built-in appliances
These switches sit above the worktop and control the power to built-in appliances below. One option is a switched fused connection unit, which is a switch with its own fuse.
Why it matters
The socket behind a built-in fridge, dishwasher or washing machine is hard to reach once it is fitted. A switch above the worktop lets you turn the appliance off without moving it.
- Good-practice gap from sink bowl
- At least 300 mm
Good to know
- The wiring regulations do not demand a switch for each appliance, but safety guidance recommends one.
- Many built-in appliance makers ask for an easy-to-reach way to disconnect the power.
- Place them like sockets: at least 300 mm from the sink bowl and not directly above the hob.
What we do We can plan appliance switches into the layout, so each built-in appliance can be switched off without moving it. Our registered electrician partner wires, tests and certifies them.
- Ceiling downlights Not in this drawing Small LED lights set into the ceiling for general light
Downlights are small LED light fittings set into holes cut in the ceiling. They spread general light across the room.
Why it matters
Each hole can weaken the ceiling's fire protection, because the fitting may resist fire far less than the plasterboard it replaces. Fittings must also stay clear of loft insulation, unless they are designed to be covered.
- Typical spacing
- 1 to 2 m apart
- Distance in from walls
- 0.5 to 1 m
- Minimum efficiency for new fixed lights (England)
- 75 lumens per circuit-watt
Good to know
- Fire-rated fittings are needed in some ceilings, such as below a room over a garage, in three-storey houses and between flats.
- Below a loft, fire-protected fittings are strongly recommended even where they are not required.
- Lighting guides suggest 1 to 2 m apart and 0.5 to 1 m from walls, placed over worktops rather than cabinets.
- The IP rating shows dust and water protection. IP20 suits most of a kitchen; IP44 (splash-proof) is advised near the sink or cooker.
What we do We can plan the lighting layout with you, and our registered electrician partner fits any downlights. We check the ceiling type first, so fire-rated fittings go where they are needed.
- Under-cabinet and plinth lighting LED strips or spots under the wall units and along the plinth
Under-cabinet lights are LED strips or small spots fixed beneath the wall units to light the worktop. Plinth lights sit in the kickboard along the bottom of the base units. Most run at 24 V from a driver, a small box that converts mains power.
Why it matters
They give task light where you prepare food, and plinth lights add a low glow for the evening. Fitted towards the front of the cabinet, they light the worktop rather than the wall.
- Usual voltage
- 24 V, through a driver
- Colour temperature for worktops
- About 4000 K
- Legal minimum colour rendering (CRI)
- 80
Good to know
- The driver must be rated above the total wattage of its lights. Guides suggest a 10 to 20% margin.
- Drivers can hide behind the plinth or inside a unit, but must stay reachable and ventilated.
- The mains connection to a driver is a job for a qualified electrician, even when the lights simply plug in.
- Natural white (about 4000 K) suits worktops. A colour rendering index (CRI) of 90 or more shows food in true colours.
What we do If you want under-cabinet or plinth lighting, we plan it with the kitchen design, so cables and drivers are hidden but reachable. Our registered electrician partner makes the mains connections.
- Pendant lights Not in this drawing Hanging lights over an island, peninsula or table
Pendants are lights that hang from the ceiling over an island, peninsula or dining table. Two or three in a row is the usual layout over an island.
Why it matters
They light the surface below and become a feature of the room. On their own dimmer, they let the same space work for cooking and for dining.
- Height above island worktop
- 700 to 900 mm
- Height above dining table
- 600 to 700 mm
- Gap between pendants
- About 600 mm
Good to know
- Lighting guides suggest 700 to 900 mm from an island worktop to the bottom of the shade.
- Over a dining table, 600 to 700 mm is typical. Taller households and larger shades need more clearance.
- Dimming needs lamps marked dimmable and a dimmer designed for LEDs.
- Put pendants on their own switch, separate from the ceiling downlights.
What we do If you want pendant lights, we agree their positions at the survey, so the ceiling cables land in the right place over your island or table. Our registered electrician partner fits and connects them.
- Light switches and dimmers Wall switches and dimmers, ideally one for each layer of light
Light switches and dimmers control the kitchen lights from the wall. Lighting guidance suggests a separate switch for each layer: ceiling, under-cabinet and feature lighting.
Why it matters
Separate switching lets you use bright task light for cooking and a softer glow later. Building regulations guidance also asks that new lights can be switched separately for each space or zone.
- Switch height in new homes (England)
- 450 to 1,200 mm above floor
Good to know
- Use a dimmer designed for LEDs, usually a trailing-edge type with no minimum load, and only dimmable lamps.
- Keep the total lamp wattage within the dimmer's LED rating. Eight 5 W downlights make 40 W.
- Old dimmers often need a minimum load that a few LEDs cannot reach, which causes flicker.
- Good practice keeps switches at least 300 mm from the sink bowl and 100 mm from the hob edge.
What we do We plan which lights go on which switch with you at the design stage. Our registered electrician partner fits LED-compatible dimmers where you want them.
- Heat alarm Not in this drawing A ceiling alarm that sounds when the kitchen gets too hot, not when you cook
A heat alarm sounds when the room reaches a set temperature. It goes on the kitchen ceiling in place of a smoke alarm.
Why it matters
Steam and cooking fumes set off smoke alarms, but they do not trigger a heat alarm. Fire service figures show about 60% of home fires start in the kitchen.
- Home fires that start in the kitchen
- About 60%
- Replace the alarm
- Every 10 years
- Distance from walls and light fittings
- At least 300 mm
Good to know
- Alarms should be interlinked, so when one sounds they all sound.
- England's regulations guidance covers escape routes such as halls and landings. The British Standard for home alarms also recommends a kitchen heat alarm.
- In Scotland every home must have a kitchen heat alarm, interlinked with smoke alarms, all fixed to the ceiling.
- Mains-powered alarms should be fitted by a qualified electrician, and are usually replaced every 10 years.
What we do Our registered electrician partner can fit a mains-powered heat alarm as part of the new kitchen electrics.
Layer 05 of 10
Air and extraction
The cooker hood, its duct to outside, any wall or ceiling fan and the trickle vents in the windows. In a refit, existing fans and hoods that vent outside are kept or replaced, and checked to be working.
- Cooker hood The hood over the hob that removes steam, smoke, grease and smells
A cooker hood draws air from above the hob through grease filters. A ducted hood sends it outside, while a recirculating hood cleans it with charcoal filters and returns it. Types include chimney, canopy, integrated, island, ceiling and downdraft, which rises from behind the hob.
Why it matters
England's guidance asks for kitchen extract to outside: at least 30 l/s through a ducted hood, or 60 l/s without one. A recirculating hood on its own does not meet this rule.
- Height above hob if no maker's figure
- 650 to 750 mm
- Minimum extract with a ducted hood (England)
- 30 l/s
- Noise in independent tests
- About 50 to 67 dB
Good to know
- Fit it at the height in the hood's instructions. With no instructions, the guidance gives 650 to 750 mm above the hob.
- Choose a hood at least as wide as the hob. Room volume in m³ times 10 to 12 gives a rough rate in m³/h.
- Wash metal grease filters about monthly. Standard charcoal filters cannot be washed and are replaced every few months to a year.
- If an open-flued gas appliance shares the room, extraction is limited and the appliance is tested with the hood running.
What we do We can fit or replace a cooker hood, and plan its duct route at the survey. Our registered electrician partner makes the electrical connection. Where an open-flued gas appliance shares the room, our Gas Safe registered partner checks it runs safely with the hood on.
- Ducting and outside vent The duct that carries air from the hood to a vent on an outside wall
The duct is the pipe that carries air from the hood to a vent on an outside wall. A non-return valve (a flap that only opens outwards) stops air and smells blowing back when the hood is off.
Why it matters
The duct has a big effect on how well the hood works. A long, narrow or bendy duct cuts airflow and adds noise.
- Preferred duct size
- 150 mm round
- Typical maximum run
- 6 m
- Flexible duct, maximum length
- 1.5 m
Good to know
- Use rigid duct wherever possible. Flexible duct is for final connections only, no longer than 1.5 m and pulled taut.
- 150 mm round duct, or a 220 x 90 mm flat equivalent, suits most hoods. 125 mm is for smaller hoods.
- Keep the run short, typically 6 m at most, and count each bend as about 1 m of extra run.
- The outside vent should have an open area of at least 90% of the duct's, so it does not choke the airflow.
What we do Where the hood is ducted outside, we plan the shortest practical duct route to an outside wall at the survey, and fit the duct, outside vent and valve along with the hood.
- Extractor fan A wall or ceiling fan that sends steamy kitchen air straight outside
An extractor fan sits in an outside wall, a window or the ceiling and blows kitchen air outside. It provides the extraction where there is no hood ducted to outside.
Why it matters
Without a ducted hood, England's guidance asks for at least 60 l/s of extract. A small bathroom-size fan, about 24 l/s in one sizing example, falls well short.
- Minimum rate with no ducted hood (England)
- 60 l/s
- Run-on time with no opening window
- At least 15 minutes
- Distance below ceiling
- No more than 400 mm
Good to know
- It should be as high as practical, no more than 400 mm below the ceiling and at least 500 mm from any trickle vent.
- Humidity sensors are allowed but need a manual override. With no opening window, the fan should run on for at least 15 minutes.
- Replacing a fan on the existing cabling does not need notifying to building control. The new fan should meet current standards.
- If an open-flued gas appliance shares the kitchen, extract is limited to 20 l/s and the appliance is tested with fans running.
What we do We can replace an old extractor fan or fit a new one during a refit, with the wiring done by our registered electrician partner. Where the guidance asks for it, the run-on timer is set to at least 15 minutes.
- Trickle vents Small slot vents in window frames that let in a steady trickle of fresh air
Trickle vents (background ventilators) are small slotted vents, usually in window frames, set at least 1,700 mm above the floor. They let in a little fresh air all the time and are meant to be left open.
Why it matters
They supply the steady background air a home needs. New windows seal more tightly than old ones, so leaving vents out can leave rooms short of fresh air.
- Kitchen vent size when windows are replaced (England)
- 8,000 mm²
- Height above floor
- At least 1,700 mm
Good to know
- If the old windows had trickle vents, the new ones should have them too, no smaller than before.
- If they had none, the usual way to comply in a kitchen is new window vents of at least 8,000 mm².
- A signed disclaimer saying you do not want vents is not a way of complying with the regulations.
- A wall vent of the right size can do the job instead of window vents.
What we do We note the room's trickle vents and windows at the survey, so the extraction we plan suits the room.
- Tumble dryer vent Not in this drawing The hose that carries damp air from a vented tumble dryer to outside
A vented tumble dryer blows damp air out through a hose. The hose must reach outside, through a window or a hole in an outside wall. Condenser and heat pump dryers need no vent.
Why it matters
The dryer type decides where it can go, because only a vented dryer needs a route outside. Under new efficiency rules, most dryers on sale from 19 January 2027 will be heat pump models.
- Most new dryers on sale are heat pump from
- 19 January 2027
- Heat pump energy use
- About half, or less
Good to know
- Condenser dryers collect water in a tank and need a well-ventilated spot. Heat pump dryers use about half the energy, or less.
- Do not enclose a dryer in a cupboard. Leave space around it and clean the lint filter after every use.
- Safety guidance recommends professional installation for vented dryers.
- A dryer's fan can pull fumes from an open-flued gas appliance, so it is included when that appliance is safety tested.
What we do We plan dryer spaces in kitchens and utility rooms around the type you have, including any vent route to outside.
Layer 06 of 10
Walls, ceiling and floor
The layers that make the room flat, dry and finished: plasterboard, plaster, damp proofing, insulation, screed, flooring, tiles and paint. Plastering comes early, once plumbing and wiring have been moved. Painting, flooring and tiling follow once the units are in. Only a floor that has to run under the units, such as a new screed, goes down first.
- Plasterboard Sheets of gypsum plaster in a paper skin that line walls and ceilings
Plasterboard is a large, flat sheet with a core of gypsum, the mineral that plaster is made from, wrapped in paper. It lines walls and ceilings, giving a flat surface ready for a thin skim of plaster or for decorating. It is either stuck to brick or block with dabs of adhesive, or screwed to a timber or metal frame.
Why it matters
In a kitchen, plasterboard is the face that tiles, paint and wall units sit against. It does not cope with water: once soaked, its strength and fire resistance cannot be relied on, even after drying. That is why leak-damaged or mouldy board is cut out and replaced during a refit.
- Standard thicknesses
- 9.5, 12.5 and 15 mm
- Sheet widths
- 900 or 1,200 mm
- Water absorbed
- under 10% for moisture-resistant board, over 25% for standard
Good to know
- Moisture-resistant board, often with a green face, is recommended for kitchen walls and ceilings. It resists damp but is not waterproof.
- Common thicknesses are 9.5, 12.5 and 15 mm. A 12.5 mm sheet weighs about 8 kg per square metre.
- Board stuck on with dabs (dot and dab) has a hollow gap behind, so unit fixings go through to the brick or block.
- On stud walls, timber or metal supports go in behind the board wherever wall or base units will be fixed.
What we do Once the old kitchen is out, we cut out damp or damaged board and re-board where needed, using moisture-resistant board. On stud walls, we fit supports behind the board where the units will hang.
- Plaster skim A thin finishing coat of plaster, about 2 mm thick, over board or old plaster
A skim is a thin finishing coat of plaster, about 2 mm thick, spread over plasterboard or older plaster. It goes on in two thin passes and sets to a smooth surface ready for decorating.
Why it matters
Units, worktops and tiles need flat walls to line up properly. A boarded wall may be out by up to 8 mm along its length, so fitters check and correct walls first.
- Skim thickness
- about 2 mm
- Drying before decorating
- typically 2 to 4 days
- Age before tiling
- at least 4 weeks
Good to know
- Fresh skim typically takes 2 to 4 days to dry, longer in a cold or damp room.
- Let it dry naturally. Heaters or dehumidifiers can cause fine cracks.
- Tile adhesive makers ask for plaster to be at least 4 weeks old before tiling.
- Moisture-resistant board needs a bonding coat before it is skimmed.
What we do We can skim walls and ceilings as part of a renovation, and allow the right drying time before tiling or decorating.
- Damp-proof course and membrane Waterproof layers in walls and floors that stop damp rising from the ground
A damp-proof course (DPC) is a waterproof layer built into a wall at least 150 mm above outside ground level. A damp-proof membrane (DPM) is a sheet or coating in a solid floor that does the same job and should join the DPC.
Why it matters
Damp often hides behind old units: mould low on cold walls, tide marks, crumbling plaster or decayed skirting. Treating it only works once the real cause is found.
- DPC height
- at least 150 mm above outside ground
- Polythene floor membrane
- at least 300 micrometres (1200 gauge)
Good to know
- There are four main kinds: condensation, rain getting in, rising damp from the ground and leaks from pipes.
- Condensation is the most common. Rising damp is often misdiagnosed, so a proper check comes first.
- Earth or paving piled above the DPC can bridge it. Removing the bridge may be enough.
- Wiping off mould will not stop it coming back. A qualified professional should find the cause.
What we do When old units come out, we look for the cause of any damp before treating it. We can carry out damp proofing as part of the job where it is needed.
- Floor insulation Rigid boards or mineral wool in the floor that cut heat loss through the ground
Floor insulation is a layer of rigid boards or mineral wool that slows heat loss through a ground floor. On a concrete floor the boards sit on the slab, under the screed. In a timber floor they fit between the joists.
Why it matters
In England, renovating more than half of a floor normally means insulating the whole floor. Insulation adds height, which can affect door openings and the level of rooms next door.
- Target for a renovated floor
- U-value 0.25 W/m²K
- Rule applies when
- more than 50% of the floor is renovated
- Payback test
- 15 years
Good to know
- A floor counts as renovated when a new layer is added, or when it is stripped back to its structure.
- The target is a U-value of 0.25, a measure of heat loss where lower is better.
- A lower standard is accepted where the target is not practical or would not pay for itself within 15 years.
- In a timber floor, insulation must not block the air bricks.
What we do If your floor is coming up, we check at the survey whether the insulation rules apply. That way the build-up and the finished floor height are planned before work starts.
- Floor screed A smooth, level layer over the concrete slab or insulation that the floor finish sits on
Screed is a layer of sand and cement, or a pumped liquid mix, spread over the concrete slab or floor insulation. It sets the exact floor height and gives a flat, level top for tiles, vinyl or wood. It is not the structure: it adds no strength to the floor itself.
Why it matters
Floor finishes need a flat, level base. Bumps and hollows show through thin floors, wear unevenly and can make tiles come loose. Screed gives that base, and can also cover insulation, a damp-proof membrane or underfloor heating pipes.
- Screed over insulation in a house
- 65 mm or more (sand and cement)
- Drying time
- about 1 day per mm for the first 40 to 50 mm
- Before tiling a sand and cement screed
- at least 3 weeks
Good to know
- Stuck (bonded) to the slab, it is often 40 mm thick. On a membrane or insulation, it is normally 65 mm or more.
- Liquid screed is pumped in and can be laid thinner, but most types do not suit floors that get wet.
- It dries slowly: roughly 1 day per mm for the first 40 to 50 mm. Cold or closed-up rooms take longer.
- Before vinyl, luxury vinyl tile (LVT) or wood goes down, a moisture test must read below 75% relative humidity (65% for wood).
What we do We check the floor's level and flatness at the free site survey. If a new screed is needed, we build its drying time into the plan so flooring is not laid too soon.
- Levelling compound A thin pourable layer that makes an existing floor smooth and flat for the new finish
Levelling compound, also called smoothing compound, is a thin pourable layer spread over a sound existing floor. It is usually 2 to 10 mm thick and sets to a smooth, flat surface for the new floor covering.
Why it matters
Thin floor coverings such as vinyl and LVT show bumps beneath them. Compound fills small dips and ridges in a sound floor, and is far thinner than a screed.
- Usual thickness
- 2 to 10 mm (up to 30 mm with added aggregate)
- Ready for floor coverings
- from about 4 hours (rapid types)
- Flatness for thin floors
- no more than a 3 mm gap under a 2 m straightedge
Good to know
- Rapid types can be walked on in 1 to 2 hours and take floor coverings after about 4 hours.
- Timber floors are first covered with plywood at least 6 mm thick, screwed down, before a flexible compound goes on.
- 'Self-levelling screed' is a liquid screed, not a levelling compound. Ask which one you are being quoted for.
- Older floors with no damp-proof membrane may need a surface membrane before the final smoothing layer.
What we do Where the floor needs it, we use levelling compound to give a flat base before the new floor goes down. Under the units, adjustable legs take up small slopes in the floor.
- Flooring The floor you walk on: tiles, vinyl, LVT, laminate or engineered wood
The floor finish is the layer you walk on. Common kitchen choices are porcelain tiles, sheet vinyl, luxury vinyl tile (LVT), laminate and engineered wood.
Why it matters
Kitchens get spills, so how a floor copes with water matters. Porcelain tile barely absorbs water and vinyl copes with surface water. Laminate resists water but is not waterproof, and engineered wood can still be damaged by moisture.
- Added floor height
- about 5 mm to 20 mm or more
- Expansion gap for click-together vinyl
- at least 5 mm
- Floor moisture before vinyl or LVT
- below 75% relative humidity
Good to know
- Floors are often laid after the units, so there is no hidden floor to pay for and replacing it later is easier.
- Run the floor right to the back of appliance spaces. Otherwise a raised floor in front can trap a dishwasher or washing machine.
- New flooring adds about 5 mm (thin vinyl) to 20 mm or more (tiles on adhesive) to the floor height.
- Click-together vinyl floors need a gap of at least 5 mm at walls and units. Where it may get wet, flexible sealant fills it.
What we do We can lay the kitchen flooring too, and plan the order of work so the floor runs into appliance spaces and finishes neatly at the plinths.
- Splashback and wall tiles The wipeable wall behind the worktop and hob, most often tiled
The splashback is the wall area behind the worktop and hob that takes splashes from washing up and cooking. It is most often tiled.
Why it matters
Tiles are heavy, and the wall behind them sets the limit on how heavy. The weight includes the adhesive and grout, and the weakest layer decides.
- Tile weight on plaster
- up to 20 kg/m²
- On unskimmed 12.5 mm plasterboard
- up to 32 kg/m²
- Plaster age before tiling
- at least 4 weeks
Good to know
- Limits are about 20 kg per square metre on plaster or skimmed plasterboard, and 32 kg on unskimmed plasterboard.
- Heavier tiles need a tile backer board, rated at around 40 to 60 kg per square metre depending on type.
- New plaster should be at least 4 weeks old before it is tiled.
- Tiles usually go on near the end of the fit, after the worktop.
What we do Where you want tiles, we tile splashbacks and walls once the worktops are in. We check the wall can carry the weight of your chosen tiles first.
- Paint and decorating The finish coats on walls and ceilings, starting with a mist coat on new plaster
Paint is the final finish on walls and ceilings. New plaster first gets a mist coat: thinned emulsion, or a primer made for new plaster, that seals the bare surface.
Why it matters
Kitchen walls get grease and cooking splashes. Kitchen paints are made to resist grease and stains, and to be washed without the colour fading.
- Mist coat (one guide)
- 60% paint, 40% water, two coats
- Scrub rating to look for
- Class 1
Good to know
- Wait until new plaster is fully dry, with no dark patches, before the mist coat.
- One guide suggests two mist coats of 60% paint to 40% water. Follow the paint maker's own advice.
- For hard wear, look for a scrubbable matt with a Class 1 wet-scrub rating.
- Paint the ceiling first, then walls, then woodwork. Touch-ups come at the end of the fit.
What we do After we plaster, we tell you when it is dry enough to paint. On a complete renovation we plan decorating around the fit, so touch-ups come last.
- Boxing-in and access panels Neat casings that hide pipes and meters, with removable panels for access
Boxing-in is a neat casing built around pipes or a meter to hide them. An access panel is a removable section that lets you reach what is inside.
Why it matters
Stop taps, valves, meters and pipe joints must stay within reach. Water regulations do not allow fittings that need turning or servicing, or pipe joints, to be hidden where access is difficult.
Good to know
- Every stop tap, valve, meter or pipe joint behind boxing needs a removable panel.
- Gas pipes may only run in a space that is properly ventilated, and not inside a wall cavity except to pass straight through.
- The gas meter must stay readily accessible for inspection and maintenance.
- Meters belong to the utility companies. Boxing goes around them, with access kept clear.
What we do Where pipes need boxing in, we box them neatly and leave access panels at valves, joints and meters. Any boxing around gas is checked by our Gas Safe registered partner.
- Sealant The flexible, mould-resistant bead at the worktop-to-wall joint and around the sink
Sealant is the flexible bead that fills joints, such as where the worktop meets the wall and around the sink. Kitchens use sanitary silicone, which contains a fungicide to resist mould.
Why it matters
It keeps water out of joints at wet edges. It stays flexible, so it copes with small movements between the worktop and the wall.
- Cure rate
- about 3 mm per 24 hours
- Keep dry for
- at least 24 hours
- Joint width
- 5 to 25 mm
Good to know
- Silicone cannot be painted. Where a joint will be painted, flexible acrylic caulk is used instead.
- It skins in about 10 minutes but cures slowly, about 3 mm deep a day. Keep it dry for at least 24 hours.
- When renewing, remove every trace of the old sealant and clean and dry the joint, or the new bead will not stick.
- Typical sealant joints are 5 to 25 mm wide.
What we do We seal worktop joints and the sink with mould-resistant sanitary silicone as part of the fit.
- Skirting and architrave The board along the bottom of the wall that covers the joint with the floor
Skirting is the board along the bottom of a wall that covers the joint between the wall and the floor.
Why it matters
Where a run of units ends, the end panel is cut to fit around the skirting, so the two meet neatly. New flooring also changes the order of work: skirting goes back on after wood or laminate floors.
- Fixings on brick or block
- about every 500 mm
Good to know
- Skirting goes on after wood or laminate floors, but before carpet.
- On brick or block it is screwed and plugged about every 500 mm. On stud walls it is glued and pinned.
- The top edge is finished with flexible decorator's caulk before painting.
- Woodwork such as skirting is painted after the ceiling and walls.
What we do Where new flooring goes down, we refit the skirting afterwards. At the end of each run, we cut the end panel neatly around it.
Layer 07 of 10
Cabinets
The cabinet boxes and the hardware that holds them: base, wall and tall units, legs, brackets, hinges, drawers and shelves. They go in after the pipes, cables and walls are ready, and before doors and worktops.
- Base units The floor-standing cupboards and drawer units that hold up the worktop
Base units are the cabinets that stand on the floor below the worktop. The usual UK carcass (the cabinet box) is 720 mm high and 560 mm deep. Widths run from 150 mm to 1,200 mm, and 600 mm is a common size.
Why it matters
They carry the worktop, the sink and built-in appliances, so they must be level and firmly joined. On 150 mm legs with a 40 mm worktop, the finished height is about 910 mm.
- Carcass height
- 720 mm (typical)
- Carcass depth
- 560 mm (typical)
- Finished worktop height
- About 910 mm
Good to know
- Sizes vary by brand. One makes base units 807 mm high and 565 mm deep, so mixed brands may not line up.
- The quoted depth includes the gap for pipes at the back, so the inside is about 510 mm deep.
- A run is set out from the corner, levelled on its legs, then bolted unit to unit near the front edge.
- Ask if units are rigid (factory-built) or flat-pack. Consumer tests found rigid units generally stronger, mainly because of their joints.
What we do At the survey we measure the room and check how level the floor is. On the day we set out the run from the corner, level each unit and bolt them together.
- Wall units The cupboards hung on the wall above the worktop
Wall units are shallow cupboards hung on the wall above the worktop. They are typically 300 mm deep and 575, 720 or 900 mm high. Widths run from 150 mm to 1,000 mm.
Why it matters
They add storage at eye level without using floor space. Their tops usually line up with the tall units, and that sets the gap above the worktop.
- Depth
- 300 mm (typical)
- Heights
- 575, 720 or 900 mm
- Gap above the worktop
- About 490 mm
Good to know
- The usual gap from the worktop to the underside of the wall units is about 490 mm, with a 40 mm worktop.
- Above the hob, the cooker hood maker's height rule applies instead. It is larger than this gap.
- One large UK cabinet maker sets a limit of 20 kg in a single-door wall unit and 30 kg in a double-door one.
- Put the heaviest things on the cabinet base, not on the shelf.
What we do We check what each wall is made of before we hang anything. Then we fix the brackets into solid masonry or timber, not plasterboard alone.
- Tall units Full-height units for a larder, built-in oven, fridge freezer or boiler
Tall units run from the floor up to the line of the wall unit tops. Common carcass heights are 1,970 mm and 2,150 mm, standing 2,120 mm and 2,300 mm on legs. They are usually 560 mm deep.
Why it matters
One tall unit can hold a whole larder, an eye-level oven or a built-in fridge freezer. Taller units need headroom to be tipped upright, so ceiling height matters.
- Carcass heights
- 1,970 or 2,150 mm
- Height on 150 mm legs
- 2,120 or 2,300 mm
- Boiler housing depth
- About 450 mm
Good to know
- Pair 720 mm wall units with 1,970 mm tall units, and 900 mm wall units with 2,150 mm tall units.
- For 2,150 mm units, allow a ceiling of about 2,370 mm so they can be stood up in the room.
- A boiler housing is shallower, about 460 mm, with no working back. The boiler's manual sets the space around it and any vents.
- Boiler makers typically ask for 600 mm of clear space in front, so an engineer can work on it.
What we do We measure the ceiling at the survey so tall units can be stood up and fixed. Around a boiler we keep the maker's clearances, and our Gas Safe registered partner does any gas work.
- Corner units Units that make use of the deep, awkward space where two runs meet
A blind corner unit is a straight unit whose closed end runs into the corner, behind the next run. An L-shaped or diagonal unit fills the corner itself, usually on a 900 by 900 mm footprint.
Why it matters
A corner is deep and hard to reach, so space is easily wasted. The type of unit and any pull-out fitting decide how much you can really use.
- L-shaped base footprint
- 900 x 900 mm
- Corner post
- About 70 x 70 mm
- Swing-out tray load
- About 25 kg per tray
Good to know
- Blind corners suit many layouts but need a corner post, about 70 mm square, so handles on the two runs do not clash.
- L-shaped units have a folding door and give full access. They are bulky and may arrive unglued to fit through a doorway.
- Swing-out trays hold about 25 kg each but need room to swing out. A sink should not go above one.
- Carousels are simpler, but round shelves waste some of a square corner. Pull-and-slide systems cost more than plain corner units.
What we do We plan corners at the survey so doors, drawers and handles clear each other. We fit and adjust any corner mechanism so it runs freely.
- Sink base unit The base unit under the sink, with a cut-down back for pipes and the waste
A sink base is a standard base unit with a lower back, about three-quarters height. The open space at the top lets the water pipes and the waste reach the sink. Some have a false drawer front instead of working drawers.
Why it matters
This cupboard often holds the main stop tap and an indoor water meter. By law the stop tap must stay easy to reach, so nothing should block it.
- Back panel height
- About 500 mm
- Widths
- 500 to 1,200 mm
Good to know
- A water meter must never be fully boxed in. Its face must stay visible, with room to replace it.
- Chipboard swells when wet. Moisture-resistant board copes with damp air, but no grade is waterproof.
- Belfast sinks need a shorter sink base, about 455 to 513 mm high.
- One supplier does not fit bins in sink units, because the pipes get in the way.
What we do We cut the back neatly around the pipes and leave the stop tap and any meter easy to reach. If a meter is in the way, any move goes through your water company.
- Drawer boxes and runners The boxes inside your drawers and the runners they slide on
The standard modern drawer is a steel-sided box with a board base, clipped onto hidden metal runners. Full-extension runners let the drawer come right out, so you can reach the back.
Why it matters
Drawers carry pans, plates and tins every day, so the runners need the right load rating. Soft-close is either built into the runner or added as an extra.
- Runner load classes
- 30 to 70 kg
- Everyday limit (one maker)
- 30 kg per drawer
- Drawer base
- 15 to 16 mm thick
Good to know
- Runners come in load classes, commonly 30, 40, 50 and 70 kg. Wide pan drawers use the higher classes.
- A rating is not an everyday target. One UK maker tells owners to keep to 30 kg per drawer.
- Dovetailed solid oak boxes are a looks upgrade. They usually run on similar runners.
- Ask whether soft-close is included on the drawers in your quote.
What we do We fit and adjust every drawer so the fronts line up and close smoothly.
- Carcass thickness The board the cabinet box is made from, and why its thickness matters
The carcass is the cabinet box: sides, top, base and back. It is usually chipboard (wood chips bonded with resin) with a hard decor face, and it costs less. MDF (medium-density fibreboard) is denser, stronger and usually a little dearer.
Why it matters
Typical cabinets are 15 to 19 mm thick, and 18 mm is usual. Thicker board is stiffer, feels more solid and lasts better, but costs more.
- Typical thickness
- 15 to 19 mm (18 mm usual)
- 18 mm against 15 mm
- About 70% stiffer
- Weight of 19 mm chipboard
- About 12.5 kg per square metre
Good to know
- A few millimetres count: 18 mm board is about 70 per cent stiffer than 15 mm, though only 20 per cent thicker.
- Chipboard holds screws well in its faces but poorly in its edges. MDF holds screws in both.
- Moisture-resistant board uses a water-resistant glue. It copes with damp air, but no grade is waterproof.
- Check the front edges. A typical rigid unit has a 2 mm plastic edging there and thin tape elsewhere.
What we do When we supply your kitchen, we go through the carcass specification with you before you order, including board thickness, backs and edging. We check every unit for damage before it goes in.
- Back panel and service void The hidden gap behind the units where pipes and cables run
Kitchen units are made with the back panel set in from the rear edge. The gap behind it, called the service void, hides pipes, wastes and cables along the wall. Back panels are solid board, commonly 8 mm thick, though one maker uses 18 mm on base units.
Why it matters
Pipes and cables can run behind the units without cutting into the cupboards. The void is part of the quoted depth, so the cupboard inside is shallower than the headline size.
- Void behind base units
- 42 mm (one maker)
- Void behind wall units
- 17 mm (one maker)
- Back panel
- 8 mm (common)
Good to know
- A typical void is 42 mm behind base and tall units and 17 mm behind wall units. Depths vary by maker.
- Check where existing pipes sit before units are ordered, in case they stand out further than the void.
- Without a void, pipes can run at leg level behind the plinth, or the units come forward with a deeper worktop.
What we do We plan pipe and cable routes around the void at the survey. Any pipes or cables that need moving are moved before the units go in, cables by our registered electrician partner.
- Adjustable legs Screw-adjustable feet that level base units on an uneven floor
Base units stand on plastic legs, usually 150 mm high, that screw up and down. They lift the units off the floor and leave the space that the plinth covers.
Why it matters
A worktop must sit level, but floors can be up to 50 mm out across one run. Turning each leg brings every unit level, though the range is small.
- Standard leg
- 150 mm
- Adjustment range
- About 140 to 170 mm
- Load rating (one maker)
- 450 kg per leg
Good to know
- A 150 mm leg adjusts from about 140 to 170 mm. Shorter 100 mm legs go down to about 90 mm.
- Where a floor is further out than the legs allow, fitters use packers or trim the legs.
- Legs are not the weak point. One maker rates its kitchen legs at 450 kg each.
- The plinth clips onto the front legs, so it can come off later.
What we do We check the floor at the survey and level every unit on its legs during the fit. Where the floor is badly out, we pack or trim the legs.
- Wall hanging brackets Hidden hooks inside wall units that hang them on a wall plate or rail
Two adjustable brackets sit inside the top back corners of each wall unit. They hook onto steel plates or a rail screwed to the wall, and a safety catch locks as the unit drops on.
Why it matters
The brackets carry the whole cupboard and everything in it. Screws inside let the fitter raise, lower and tilt each unit so a row lines up.
- Load per bracket
- About 30 to 55 kg
- Height adjustment
- About 13 to 18 mm
- Space above to lift the unit on
- About 100 mm
Good to know
- Bracket makers rate them at about 30 to 55 kg each. The fixing into the wall is usually the weak point.
- Fixings are not supplied with units, because the right screw depends on the wall.
- Plasterboard stuck onto brick with blobs of adhesive (dot and dab) has a gap behind, so screws must reach the brick.
- On a stud wall, timber or metal support is fixed behind the board, before boarding, where units will hang.
What we do We check each wall at the survey and choose fixings that bite into masonry or timber. We hang, level and line up every wall unit on its brackets.
- Hinges Hidden hinges that hold each door and let it be lined up
Kitchen doors hang on concealed hinges, hidden inside when the door is shut. A 35 mm round cup sits in the back of the door, and an arm clips onto a plate inside the cabinet.
Why it matters
Three screws on each hinge move the door side to side, in and out, and up and down. That is how a fitter makes the gaps between doors even.
- Hinge cup
- 35 mm
- Standard opening
- About 110 degrees
- Hinges on a full-height larder door
- 4
Good to know
- Soft-close is now usually built into the hinge. Older or cheaper hinges take a clip-on damper.
- A standard hinge opens about 110 degrees. Wide-angle hinges of 155 to 170 degrees suit corner and folding doors.
- The number of hinges depends on door height and weight. A 715 mm base door has two, a full-height larder door four.
- A stop can limit a door to about 86 degrees where it would hit a wall.
What we do We adjust every hinge at the end of the fit, so doors sit straight with even gaps and close softly.
- Shelves and supports Shelves on small pegs that move up and down, plus fixed shelves in tall units
Adjustable shelves rest on small pegs pushed into rows of 5 mm holes in the cabinet sides. The holes are 32 mm apart, so you can move a shelf up or down. Tall larders also have one fixed shelf, glued in for strength.
Why it matters
Every shelf bends a little under weight, and wide shelves bend more. Wood-based boards also keep sagging slowly under a steady load.
- Peg hole spacing
- 32 mm
- Extra sag over time
- About 50%
- Wall unit shelf depth
- About 255 mm
Good to know
- Doubling a shelf's width makes it sag about eight times as much. Keep heavy items on short shelves or the cabinet base.
- Shelves that only rest on pegs can tip. Better cabinets use supports that lock the shelf in place.
- Wall units 575 mm high usually have one shelf. Those 720 or 900 mm high usually have two.
What we do We can set shelves at heights that suit what you plan to store, and fit locking supports where the units include them.
- Cams, dowels and fixings The dowels, cams and bolts that hold each unit together and to the next
Rigid units are built in the factory with glue and dowels (wooden pegs), so nothing can work loose. Flat-pack units use cam fittings: a metal disc in one panel turns to grip a bolt from the next.
Why it matters
Joints decide how strong a cabinet is. Consumer tests found flat-pack ranges generally weaker than the same brand's rigid units, mainly because of their joints.
- Connector bolt holes
- 5 mm
- Screws from a board edge
- At least 8 mm (25 mm from a corner)
Good to know
- Units in a run are clamped, then joined with two-part connector bolts through 5 mm holes near the front edge.
- Chipboard grips screws poorly in its edges. Good fittings screw into the board face instead.
- Rigid units can be ordered unglued (dry assembled) when they need altering on site or will not fit through a door.
- Tall units are fixed back to the wall with L-shaped brackets.
What we do Flat-pack units are assembled on site, and we bolt every run together. Tall units are fixed back to the wall.
- Pull-outs and internal storage Pull-outs, corner fittings and bins that make the inside of a unit easier to use
Internal storage means fittings that slide or swing out, so you can reach the back of a cupboard. In corners these include carousels, swing-out trays and pull-and-slide systems.
Why it matters
Deep and corner cupboards are hard to reach without them. Each fitting has a load rating and needs space to move, so it has to be planned with the units.
- Corner tray rating
- About 25 kg per tray
- Pull-and-slide corner system
- About 32 kg in all
Good to know
- Corner trays and carousel shelves are typically rated about 25 kg each. Pull-and-slide corner systems carry about 32 kg in all.
- Swing-out trays stick out about 13 cm past the door when open and need about 30 cm of side space.
- One supplier does not fit bins in sink units, because the pipes get in the way. Check where the bin will go.
What we do We fit and adjust pull-outs so they run smoothly and clear the doors, handles and pipes around them.
- Island or peninsula Not in this drawing A block of units standing clear of the walls, or joined to a run at one end
An island is a block of base units standing in the room, clear of the walls. A peninsula is similar but joins a wall or run at one end. Either can hold a sink or a hob.
Why it matters
Any sink, hob or lights on an island need water, waste, power or extraction brought out to it, away from the walls.
- Pendant height above the worktop
- 70 to 90 cm
Good to know
- Moving the sink to an island usually needs Building Regulations approval when it means new connections to a drain or stack.
- A long or steep sink waste may need a vent, such as a one-way air valve, so the trap keeps its water.
- Island cooker hoods hang from the ceiling. A downdraft extractor rises from the worktop behind the hob instead.
- Pendant lights over an island usually hang 70 to 90 cm above the worktop.
What we do At the survey we check how water, waste, power and extraction can reach an island before the design is fixed.
Layer 08 of 10
Doors and trims
The parts you see and touch: doors, drawer fronts, handles, end panels, plinth and trims. They go on near the end of a fit, once the cabinets are level and fixed.
- Shaker doors A framed door with a flat, recessed centre panel
A Shaker door is a frame of four strips around a flat centre panel that sits slightly back. It is named after the Shakers, a religious group whose early meetings were in Bolton, Lancashire, around 1747. Their furniture was plain and practical.
Why it matters
Frame width changes the look: wide frames feel traditional, narrow frames more modern. It is also far easier to clean than ornate doors.
- Frame width
- 50 to 115 mm
- Panel recess
- 7 to 11 mm
- Door thickness
- 18 to 22 mm
Good to know
- A standard frame is about 105 to 115 mm wide. A slim, or skinny, Shaker frame is about 50 to 75 mm.
- Five-piece doors are built from separate timber parts and show grain through paint. One-piece MDF doors cost less and stay smooth.
- Lay-on doors cover the cabinet front. In-frame doors sit inside a frame, cost roughly 15 to 30 per cent more and need precise fitting.
- Dust gathers on the ledge where frame meets panel. Wipe it with a soft, damp cloth.
What we do We hang and adjust every Shaker door so the frames line up across the run and the gaps are even.
- Slab doors A flat door with no frame or panel, for a clean, modern look
A slab door is one flat panel with no frame, groove or recess. It gives a modern, minimal look, in finishes from matt and gloss to real wood veneer and woodgrain.
Why it matters
With no ledges for dust, it is quick to wipe clean. The finish you pick decides how it wears and how much fingerprints show.
- Door thickness
- 18 to 22 mm
- Veneer layer
- 0.5 to 2 mm
- Heat limit on doors (one maker)
- 60 °C
Good to know
- Wrapped (plastic film) doors are tough but cannot be repaired once damaged. Chipped veneer usually means a new door.
- Fingerprints show most on dark gloss and least on light matt, textured or woodgrain finishes.
- Veneer is a 0.5 to 2 mm slice of real wood. It can fade or change colour in sunlight.
- Keep kettles, toasters and air fryers out from under wall units. Heat and steam cause most door damage.
What we do We fit heat deflector strips beside ovens and dishwashers where the door maker asks for them. Without them, heat damage may not be covered by the door guarantee.
- Handles Bars, knobs and cups fixed to each door and drawer front
Handles come as bars, D-shapes, T-bars, knobs, cups and flush pulls. A two-screw handle is sized by its centres: the distance between its two fixing holes.
Why it matters
You grip them many times a day. D-handles are easy to hold, textured finishes add grip, and darker handles are easier to see with weaker eyesight.
- Common centres
- 96, 128, 160 mm and more
- Distance from the door edge
- About 64 mm
- Gap to a side wall
- About 50 mm
Good to know
- There is no single standard size. Centres on sale include 96, 128 and 160 mm and many others.
- Doors arrive without holes. Drilling for handles is the fitter's last job, so every handle lines up.
- By convention, handles go at the top corner of base doors and the bottom corner of wall doors, about 64 mm in.
- Handles stick out, so allow about 50 mm between a unit and a side wall.
What we do We drill and fit the handles as our last job, setting them out so they line up across every door and drawer.
- Handleless Doors with no handles: a recessed rail, a grip built into the door, or push-to-open
True handleless uses a recessed rail fixed into the cabinet, leaving a finger gap behind the door edge. J-profile grip doors have a J-shaped grip cut into the door's own edge. Push-to-open doors pop open when you press them.
Why it matters
It gives clean, unbroken lines, and nothing sticks out to catch in a tight space. The trade-offs are cost, cleaning and, for some people, grip.
- Gap to a side wall
- About 30 mm
- Gap for each upright rail
- About 30 to 35 mm
- Plinth height (one true handleless system)
- 160 mm
Good to know
- True handleless needs purpose-made cabinets with notched sides and shorter doors. It is more complex to fit.
- A J-profile grip adds little cost, as the grip is part of the door. Rails and push-to-open add hardware and fitting time.
- Rails and grooves collect crumbs and need regular wiping. Fingerprints show most on dark gloss.
- Push-to-open needs a press some people find less natural, and its catches may need replacing in time.
What we do We fit rails, J-profile grip doors and push-to-open catches to the maker's guide, keeping the finger gaps even along the run.
- End panels Panels that finish the exposed side of a run so it matches the doors
An end panel is a board in the door finish, fixed over the visible side of a unit. It is needed wherever a unit side shows and the cabinet colour differs from the doors.
Why it matters
It makes the end of a run look finished instead of showing plain cabinet board. Panels come oversize so the fitter can scribe them, trimming the edge to follow an uneven wall or floor.
- Thickness
- 18 to 19 mm
- Added to the run length
- About 18 to 25 mm
Good to know
- Panels are about 18 to 19 mm thick and add roughly 18 to 25 mm to a run. Allow for this when planning.
- They are screwed on from inside the unit, so no fixings show.
What we do We scribe each end panel on site so it sits tight to the wall and floor, then fix it from inside the unit.
- Plinth The board along the bottom of the base units that hides the legs
The plinth, also called the kickboard, runs along the bottom of the base units. The standard UK height is 150 mm, to match the standard legs.
Why it matters
It hides the legs and stops crumbs and dirt collecting under the units. It is not fixed for good: clips on its back spring onto the legs, so it can come off.
- Standard height
- 150 mm
- Lower option
- 100 mm (with 100 mm legs)
- Minimum for most plinth heaters
- 120 mm
Good to know
- Where the floor is not level, the plinth is cut to follow it.
- Seal the bottom edge with a clear plastic strip or waterproof glue, so mopping water cannot swell the board.
- A plinth heater needs a plinth at least 120 mm high, or 80 mm for slim models, plus a cut-out for its grille.
- LED plinth lights run from a driver that can sit behind the plinth, but it must stay reachable.
What we do We cut the plinth to the floor, seal its bottom edge and clip it on so it can come off later.
- Cornice and pelmet Trims above the wall units (cornice) and below them (pelmet)
Cornice is a trim along the top of wall and tall units, closing the gap towards the ceiling. A pelmet, or light rail, is a smaller trim under the wall units that hides the lights.
Why it matters
Both are optional, and many modern kitchens leave them out. Cornice and the tops of wall units collect dust, which is one reason some kitchens run units to the ceiling.
- Trim lengths
- 2.4 to 3 m
Good to know
- Trims usually come in lengths of 2.4 to 3 m.
- When measuring the gap above the worktop, measure to the wall unit itself, not to the pelmet.
What we do We cut and fit cornice and pelmet on site where your design includes them.
- Fillers and scribes Narrow strips that close the gap between a unit and an uneven wall
A filler, or scribe, is a narrow strip in the door finish that closes the gap between the last unit and a wall. The fitter trims it to follow the wall's actual line.
Why it matters
Walls are rarely straight or square. Fillers also hold units a little off the wall, so doors and drawers can open fully.
- Gap with handles
- About 50 mm
- Gap with handleless
- About 30 mm
- Wall flatness allowance
- Up to 8 mm
Good to know
- A finished plasterboard wall may be up to 8 mm out over its length and still meet the usual standard.
- Allow about 50 mm between a unit and a side wall with handles, or about 30 mm with handleless doors.
- Units are not made narrow enough for gaps under 150 mm, so those gaps take a filler.
- Forgetting fillers is a common design mistake. Doors then jam on walls, and drawers hit the next unit's handle.
What we do We plan fillers at the survey, then scribe each one on site to the real shape of the wall.
- Integrated appliance doors Kitchen doors fixed to a built-in dishwasher, fridge or freezer
An integrated appliance sits behind a door that matches the kitchen. With a fixed (door-on-door) hinge, that door screws straight onto the appliance door. With a sliding hinge, it hangs on the cabinet's hinges and a slider links the two.
Why it matters
The furniture door has to line up with the doors beside it. On a fridge freezer, the split between the two doors must match the appliance.
- Gap between doors
- 3 to 5 mm
- Full-size dishwasher door
- 715 x 597 mm
- Fridge freezer splits
- 50/50, 60/40 or 70/30
Good to know
- A replacement appliance should use the same hinge type. Converting may need a kitchen fitter.
- A 70/30 fridge freezer needs different doors from a 50/50 one. A 3 to 5 mm gap is left between doors.
- A built-in dishwasher needs no cabinet. A notch is often cut in the top of the plinth so its door can drop open.
- Do not open a dishwasher mid-cycle or straight after. Steam is a main cause of door damage.
What we do We hang appliance doors so they line up with the run. We leave the dishwasher's hoses and cable long enough to pull it out later.
Layer 09 of 10
Worktops and sink
The working surface, its joints and upstands, and the sink and tap set into it. Worktops go on once the base units are fixed, then the sink and tap follow; stone-type tops are templated first and fitted about one to two weeks later.
- Worktop The flat working surface fixed on top of the base units
The worktop is the surface you prepare food on, fixed on top of the base units. Common materials are laminate, solid timber, quartz, granite, ceramic and porcelain.
Why it matters
It takes heat, water, knocks and daily cleaning, so the material decides how much care it needs. It also sets the fitting order, because stone-type tops are made to measure after the units go in.
- Typical thickness
- 20 to 40 mm (most often 28 or 38 mm)
- Usual depth
- 600 or 900 mm
- Template to fitting (one supplier)
- one to two weeks
Good to know
- Most worktops are 20 to 40 mm thick, most often 28 or 38 mm, and 600 or 900 mm from front to back.
- Laminate and timber tops are cut and fitted on site. Quartz, granite, ceramic and porcelain tops are templated once the units are fixed and level.
- Quartz is not fully heat resistant because of the resin in it, so stand hot pans on a trivet.
- Granite needs resealing about once a year. Timber needs oiling roughly every three to six months.
What we do We fit laminate and solid timber tops on site. For quartz, granite, ceramic and porcelain we fix and level the units first so the tops can be templated.
- Worktop joints Where two lengths of worktop meet, at a corner or along a run
A worktop joint is where two pieces of worktop meet. Laminate corners usually use a mason's mitre, a shaped corner cut with a jig and router, pulled tight by bolts underneath. Solid timber tops use plain butt joints, also bolted from below.
Why it matters
A joint is the weak point for water, and laminate joints near a sink are at particular risk. Stone is weaker where a joint meets a sink or hob cut-out.
- Distance from a cut-out
- at least 100 mm
- Bolts per timber joint
- 3
- Longest stone piece (one supplier)
- about 3 m
Good to know
- Keep joints at least 100 mm from a sink or hob cut-out. One stone supplier prefers 300 mm.
- Laminate joints are sealed with jointing compound before the bolts are tightened evenly.
- Timber tops usually take three bolts per joint, with the end grain oiled first.
- Stone pieces are usually limited to about 3 m long, so a long run or an L-shape needs a joint.
What we do We plan where the joints fall at the survey, away from the sink and hob where the layout allows. On laminate and timber we cut, seal and bolt the joints ourselves.
- Upstand The low strip along the wall at the back of the worktop
An upstand is a short strip fixed along the wall where it meets the worktop. A splashback is a taller panel, usually behind the hob or sink, or across a whole wall.
Why it matters
It covers the small gap left between worktop and wall, which timber and stone tops need. The joint is finished with silicone, or with tiles above, so water stays out.
- Laminate upstand height
- around 120 mm
- Stone upstand height
- up to 200 mm
- Splashback thickness
- about 20 mm
Good to know
- Laminate upstands are around 120 mm high. Granite, quartz and other stone upstands can be up to 200 mm.
- Laminate upstands are not recommended around the hob.
- A splashback is about 20 mm thick, so it takes about 20 mm off the usable worktop depth.
- For full-height stone splashbacks, the hood, wall units and sockets must be in place before the template visit.
What we do We fit and seal upstands and splashbacks as part of the worktop work. We also tile splashbacks where you prefer tiles.
- Sink The bowl set into the worktop, with its waste and trap underneath
An inset sink drops into a hole from above and rests on the worktop. An undermount sink fixes underneath the worktop. A Belfast sink is a deep ceramic sink set at the front edge, with its front showing.
Why it matters
The sink type limits the worktop, and the worktop limits the sink. Undermount sinks need a solid, water-resistant top, because a cut laminate edge exposes the board inside.
- Cut-out from front edge of worktop
- at least 50 mm
- Cut-out from back edge of worktop
- at least 60 mm
- Stone between tap hole and sink cut-out
- at least 50 mm
Good to know
- Inset sinks suit every worktop, including laminate and timber.
- Avoid undermount and Belfast sinks with standard laminate. One worktop supplier says the damage cannot be mended.
- Stainless steel is durable and good value. Composite is tough and heat resistant. Ceramic is heavy but does not dent.
- Belfast sinks are heavy and need strong support underneath to stay level.
What we do At the survey we check the sink type suits the worktop you have chosen. We fit and plumb the sink and seal the cut-out with silicone.
- Kitchen tap The mixer tap at the sink, sometimes with a spray, filter or boiling water
Most kitchen taps are mixers that blend hot and cold through one spout. A pull-out tap has a spray head on a long hose. Filtered and boiling-water taps add units in the cupboard under the sink.
Why it matters
A tap must suit your water pressure, or the flow will be weak. The kitchen cold tap is usually your drinking water, so it should stay unsoftened.
- Low pressure
- under 1 bar
- Boiling-water tap minimum pressure (two makers)
- 1.5 to 2 bar
- Usual tap hole
- 35 mm
Good to know
- Each metre of drop from a loft tank gives about 0.1 bar. Below 1 bar counts as low pressure, so choose a tap rated for it.
- Water companies must keep at least 0.7 bar in the pipe to your home, measured at the outside stop valve.
- A boiling-water tap needs a tank under the sink, a 13 A socket, isolating valves and enough mains pressure.
- Change filter cartridges when the maker says. An old cartridge stops working and can release bacteria.
What we do At the survey we can check your water system and pressure before you choose a tap. We fit the tap and its connections with the sink.
Layer 10 of 10
Appliances
Cooking, cooling and laundry appliances, either built in behind furniture doors or freestanding. They go in near the end of a fit, after the worktops and sink, with gas and new circuits handled by registered trades.
- Hob The cooking surface set into the worktop: gas, ceramic or induction
A hob is the cooking surface built into the worktop. Gas hobs burn gas under pan supports, ceramic hobs heat the glass, and induction hobs make heat in the pan itself.
Why it matters
Each type needs a different supply, and that decides who fits it. Gas hobs need a Gas Safe registered engineer, and most electric hobs are wired in by an electrician.
- Hood height if no maker's figure
- 650 to 750 mm
- Hob to side wall (one maker)
- 150 mm
- Sockets and switches from hob edge
- at least 100 mm to the side
Good to know
- Many gas hobs also need a 13 A socket to power the ignition.
- Switching from gas to induction usually means capping the gas and adding a dedicated electrical circuit.
- Stone and quartz tops cannot be cut in place, so a bigger hob later may mean a new worktop.
- Hood height follows the maker's instructions. Without one, a ducted hood goes 650 to 750 mm above the hob.
What we do We cut the worktop and fit the hob to the maker's clearances. Gas hobs are connected by our Gas Safe registered partner, and new cooker circuits by a registered electrician we partner with.
- Oven A built-in oven, under the worktop or at eye level in a tall unit
A built-in oven sits either under the hob (built-under) or at eye level in a tall housing unit. All are 60 cm wide: single ovens are 60 cm high, double ovens 70 or 90 cm, and compact ovens 45 cm.
Why it matters
Where it goes changes the housing, the airflow and the power supply. Eye level makes it easier to get food in and out, while built-under keeps the oven below the hob.
- Single oven
- 60 cm wide x 60 cm high
- Double oven
- 60 cm wide x 70 or 90 cm high
- Compact oven
- 60 cm wide x 45 cm high
Good to know
- Most electric ovens are wired in by a professional. Plug-in models exist but are few.
- Guidance suggests cooking appliances over 2 kW have their own circuit. An oven under 3 kW may go on the ring if it stays within capacity.
- Connecting an oven to an existing cooker circuit is not notifiable work. A new cooker circuit is.
- Ovens need air: one maker asks for a 45 mm gap behind in a tall unit and a 100 cm² vent at the base.
What we do We build the oven into its housing with the gaps and vents the maker asks for. Our registered electrician partner connects it and adds a cooker circuit where one is needed.
- Range cooker Not in this drawing A wide freestanding cooker with several ovens and a large hob
A range cooker is a freestanding cooker, usually 90, 100 or 110 cm wide, with five to eight cooking zones. It comes as gas, dual fuel (a gas hob with electric ovens), electric or induction.
Why it matters
It needs its own gap in the units and its own supplies, so plan it before the units are ordered. Your fuel supply may decide the type, because switching costs extra.
- Common widths
- 90, 100 or 110 cm
- Gas point height (one maker)
- at least 750 mm above the floor
- Cooker circuit (one 90 cm dual fuel model)
- 32 A
Good to know
- Gas and dual fuel range cookers must be installed by a Gas Safe registered engineer.
- One maker asks for a bayonet gas point behind the cooker, within 1 m of it and at least 750 mm above the floor.
- The cooker switch must stay reachable and should not sit directly behind the cooker. A plain 13 A socket is not suitable.
- Freestanding gas cookers come with a bracket fixed to the wall that stops them tipping forward.
What we do We leave the right gap in the run and plan the gas point and cooker switch at the survey. Our Gas Safe registered partner connects gas models and fits the stability bracket.
- Built-in microwave and compact ovens Not in this drawing A microwave or compact oven built into a wall or tall unit
A built-in microwave is made to sit flush inside a kitchen unit, usually a wall unit or tall housing. Standard models fit a 60 cm wide unit and are usually around 45 cm high.
Why it matters
Built-in models need air to get rid of the heat they make while cooking. They also need a supply you can switch off without pulling the appliance out.
- Standard built-in height
- around 45 cm
- Compact built-in height
- 30 to 45 cm
- Unit width
- usually 60 cm
Good to know
- Most built-in microwaves have no plug and are wired in by a qualified electrician.
- Combination microwaves need more ventilation space than solo models.
- If the switch ends up hidden inside the housing, makers ask for a separate isolating switch you can reach.
- Fit it no higher than about the shoulder height of the person who cooks most.
What we do We build the microwave into its housing with the maker's ventilation gaps. We plan an isolating switch you can reach, and our registered electrician partner wires its supply.
- Fridge freezer The fridge freezer, hidden behind unit doors or standing on its own
An integrated fridge freezer sits inside a tall housing behind furniture doors. A freestanding one stands on its own, and American-style models are wider, usually about 90 cm.
Why it matters
Integrated models need the right housing, door split and airflow to run well. Without enough air they run longer, cost more and can fail early.
- Integrated unit width
- 60 cm
- Housing vents (one maker)
- at least 200 cm² top and bottom
- American-style width
- usually 90 cm
Good to know
- Integrated models fit a 60 cm wide unit, are usually 55 cm deep and range from about 100 to 200 cm high.
- The fridge to freezer split, such as 70/30, must match your furniture doors. Choose the same split when you replace one.
- One maker asks for at least 200 cm² of ventilation at the top and at the bottom of the housing.
- Ice and water dispensers need a plumbed water supply, usually within 3 to 5 m.
What we do We build in integrated fridge freezers with the vents the maker asks for and line up the doors. We can run a water feed for an ice maker as part of the plumbing work.
- Dishwasher A dishwasher that slides in under the worktop between base units
Full-size dishwashers are 60 cm wide and slimline ones 45 cm. A fully integrated model hides behind a furniture door, while a semi-integrated one leaves its control panel showing.
Why it matters
It needs water, a drain and power, run to one side so the machine can slide out for servicing. It also has to fit the height under the worktop, now and after any new floor.
- Full-size width
- 60 cm
- Slimline width
- 45 cm
- Height under the worktop (one supplier)
- up to 870 mm
Good to know
- An integrated dishwasher needs no cabinet of its own. It sits between two units on the usual 150 mm plinth.
- One maker asks for the hoses and plug to reach at least 60 cm, so the machine can come out still connected.
- Do not tile up to the front of a fitted dishwasher. A raised floor can trap it under the worktop.
- The furniture door must suit the machine. One maker allows door panels of 2.5 to 8 kg.
What we do We plumb and connect the dishwasher and fit its furniture door. We plan the floor so the machine can still come out later.
- Washing machine The washing machine, in a 60 cm space under the worktop
A washing machine under the worktop sits in a 60 cm wide space. Integrated models hide behind a furniture door, and freestanding models show their own front.
Why it matters
It needs cold water, a drain and power, and it shakes on the spin. Setting it level on a firm floor keeps noise and vibration down and stops it wandering.
- Space width
- 60 cm
- Drain hose height (one maker)
- 60 to 100 cm
- Water pressure (one maker)
- 1 to 10 bar
Good to know
- Most connect to cold water only. One maker asks for 1 to 10 bar of water pressure.
- The drain hose usually rises 60 to 100 cm, then goes into a standpipe or the side outlet on the sink trap.
- On a timber floor, one maker asks for a corner spot and a water-resistant board at least 30 mm thick.
- Integrated models offer fewer choices and cost more to install than freestanding ones.
What we do We plumb in the cold feed and waste and set the machine level. On timber floors we check the floor before choosing its spot.
- Tumble dryer Not in this drawing A clothes dryer: vented, condenser or heat pump
A vented dryer blows damp air outside through a hose. A condenser dryer collects the water in a tank. A heat pump dryer reuses warm air and sends water to a tank or drain.
Why it matters
The type decides where it can go. Vented models need a window or wall vent nearby, while condenser and heat pump models need no hole in the wall.
- Heat pump energy use
- less than half of vented or condenser
- Mostly heat pump models on sale from
- 19 January 2027
Good to know
- Heat pump dryers use less than half the energy of vented or condenser models.
- From 19 January 2027 most dryers on sale will be heat pump models. Washer-dryers are not affected.
- Stack a dryer on a washing machine only with a stacking kit, dryer on top. Without one it can fall.
- Do not shut a dryer in a cupboard. Leave space around it and clear the lint filter after every use.
What we do We plan the dryer's space, airflow and any wall vent at the survey, including in utility rooms.
- Wine cooler Not in this drawing A small fridge for bottles, built in under the worktop
An under-counter wine cooler fits below the worktop like a base unit. Widths run from slim 15 cm models to full 60 cm ones.
Why it matters
Like any fridge it has to get rid of heat. Built-in models take their air through the plinth, so the vent there must stay clear.
- Widths
- 15 to 60 cm
- Plinth vent (one maker)
- at least 200 cm²
Good to know
- One maker recommends a plinth vent of at least 200 cm² for its built-in model.
- Never block or cover the air vents.
- Integrated models sit flush with the cupboards around them.
- Slim 15 cm models suit small or awkward gaps in a run.
What we do We fit built-in wine coolers with a vented plinth to the maker's figure.
- Waste disposal unit Not in this drawing A grinder under the sink that washes food scraps into the drain
A waste disposal unit fits under the sink outlet and grinds food scraps so they wash away with water. It runs on mains power and is switched from above the worktop or by an air button.
Why it matters
It sends food into the drains. The water companies' trade body does not recommend these units, saying sewers were not designed for food waste.
- Switch distance from sink (one maker)
- at least 1 m
- Water used (trade body figure)
- just over 12 litres per kg of food
Good to know
- One maker asks for a switched, fused supply above the worktop, at least 1 m from the side of the sink.
- Some units use an air switch: a push button on the sink or worktop instead of a wall switch.
- Run cold water while grinding, and keep fat, oil and grease out of the drain.
- The trade body puts water use at just over 12 litres for each kilogram of food waste.
What we do We explain the drainage concerns at the survey. If you go ahead, we fit the unit to the sink waste, and our registered electrician partner adds its switched supply.
Before you choose
Choices, explained.
The decisions people ask us about most, set out plainly.
Handles or handleless?
Handles, J-profile grip doors and true handleless rails all open the same cupboards. They differ in look, cost, cleaning and how easy they are to grip.
Handles
An easy grip, a lower cost and a look you can change later
- A clear grip: D-handles are easy to hold, and darker ones are easier to see
- Usually costs less than true handleless or push-to-open
- Uses standard cabinets and doors, so fitting is simpler
- Handles can be swapped later, if the new ones match the existing holes
- They stick out and can snag in tight spaces
- Units beside a wall need a gap of about 50 mm
- There is no single standard size, so replacements are limited by the holes
J-profile grip doors
A handleless look without the cost of rails
- The grip is cut into the door, so it adds little cost
- A defined grip many people find easy, including those with weaker hands
- Nothing sticks out to snag in tight spaces
- The groove collects crumbs and needs regular wiping
- Corners need matching corner posts to carry the line round
- Fingerprints show on the edges you touch, most on dark gloss
True handleless and push-to-open
Clean, unbroken lines where the budget allows
- Smooth, unbroken fronts that can make a small kitchen feel bigger
- Nothing sticks out to snag
- Push-to-open still works if someone pulls instead
- Needs purpose-made cabinets and more complex fitting, so it costs more
- Rails need regular wiping
- Push-to-open needs a press some find less natural, and catches may need replacing
- Can be harder to open for people with limited hand strength
In shortIf grip and cost come first, handles or J-profile grip doors are the simpler route. If clean lines matter more to you, true handleless gives them, with more cost and cleaning.
Shaker or modern?
Door style sets the look of the whole kitchen. Shaker is the framed, classic door, and slab is the flat, modern one.
Shaker
Traditional rooms, or a softer modern look with slim frames
- Frame width sets the mood: wide frames feel traditional, a 75 mm frame more modern
- Far easier to clean than ornate doors
- Can be fitted in-frame, with the door set inside a frame on the cabinet
- Timber five-piece versions show real grain, even through paint
- Dust and crumbs gather on the ledge around the panel
- Timber five-piece doors cost more than one-piece MDF
- In-frame costs roughly 15 to 30 per cent more and needs precise fitting
Slab
Modern, minimal kitchens
- No grooves or ledges, so it is quick to wipe clean
- A wide choice of finishes: matt, gloss, veneer and woodgrain
- A clean, minimal look
- Fingerprints show, most on dark gloss
- Wrapped doors cannot be repaired once damaged
- Veneer can fade in sunlight, and a chipped door is usually replaced
In shortChoose by the look you want and how you like to clean. Shaker brings a framed, classic face with a ledge to wipe, and slab a flat face where the finish decides the upkeep.
Carcass thickness, explained
The carcass is the cabinet box. UK cabinets are typically 15 to 19 mm thick, and a few millimetres make more difference than you might expect.
15 or 16 mm board
Lower-cost ranges and lighter loads
- Costs less than thicker board
- Lighter to carry and fit, since weight rises with thickness
- Less stiff: 18 mm board is about 70 per cent stiffer than 15 mm, and about 40 per cent stiffer than 16 mm
- Shelves and long side panels sag more under weight
- Feels less solid than thicker cabinets
18 mm board
The usual UK choice, for rigid and flat-pack units alike
- The typical UK thickness, so it is easy to compare ranges like for like
- Feels more solid and lasts better than thinner board
- About 70 per cent stiffer than 15 mm board
- Costs more than thinner board
- Wide shelves still sag, so keep heavy items low
19 mm board
Wide shelves and heavier loads
- About 67 per cent stiffer than 16 mm board
- Feels solid, and thicker cabinets tend to last better
- Heavier: 19 mm chipboard weighs about 12.5 kg per square metre
- Costs more
- Only 1 mm thicker than 18 mm, so the gain over 18 mm is small
In shortThickness matters for shelves and wide panels, where a few millimetres change sag a lot. Ask about the joints, back panel and edging too, since tests found weak joints held flat-pack units back.
Laminate, timber or stone?
Worktops fall into three groups: laminate, solid timber, and stone-type tops (quartz, granite, ceramic and porcelain). They differ in care, heat resistance and how they are fitted.
Laminate
A lower outlay and a top fitted on the day
- Costs less than other materials and is easy to keep clean
- Needs no oiling or sealing
- Cut and fitted on site, so there is no wait for templating
- Scratches, and cannot take hot pans
- The face can lift if water gets into a joint or edge, so joints near the sink are a risk
- Not suited to undermount or Belfast sinks
Solid timber
A warm, natural look in a kitchen you are happy to look after
- Fairly low cost among natural materials
- Marks can be sanded away
- Cut and fitted on site
- Scratches and dents, and is sensitive to heat and water
- Needs oiling roughly every three to six months
- Needs expansion gaps, and a moisture barrier over a dishwasher or washing machine
Quartz, granite, ceramic or porcelain
Long wear, stain resistance and undermount sinks
- Quartz resists scratches and stains and needs no sealing
- Granite is hard to scratch and takes hot pans; it needs resealing about once a year
- Porcelain is hard and highly heat resistant
- Templated after the units are fixed, then fitted about one to two weeks later
- Cutting makes silica dust, so cut-outs are made in a workshop and cannot easily be changed on site
- Quartz is not fully heat resistant, and porcelain is more easily chipped by heavy knocks
In shortLaminate and timber suit a quicker fit and a lower outlay, as long as you accept more care. Stone-type tops suit you if heat, stains and an undermount sink matter more than waiting for templating.
Screed or levelling compound?
Both give the new floor finish a flat base. Screed is a thick layer that builds a floor up, while levelling compound is a thin pour that smooths a floor already in place.
Screed
Rebuilding a floor, covering insulation or heating pipes, or large changes in level
- Sets a defined floor level and carries the floor finish
- Can cover insulation, a damp-proof membrane or underfloor heating pipes
- Liquid screeds can be thinner: 25 to 35 mm
- Sand and cement screed is thick: 25 mm at the least when bonded, and 65 to 75 mm over insulation
- Slow to dry: roughly a day per millimetre at first, so 50 mm can take about two months
- Liquid calcium sulphate screeds are not suited to floors that will get wet
Levelling compound
Smoothing a sound floor that is only slightly uneven
- Thin: usually 2 to 10 mm, or up to 30 mm with added aggregate
- Can be walked on after one to two hours
- Floor coverings can often go down after about 4 hours
- Only goes over a sound, dry base and does not fix a weak floor
- Timber floors need at least 6 mm plywood screwed down first
- Damp floors may need a surface damp-proof membrane before it goes down
In shortIf the floor is sound and only a few millimetres out, levelling compound is the quicker fix. If the floor is being rebuilt, insulated or heated, screed does that job, with drying time to plan for.
Radiator, plinth heater or underfloor heating?
New units often cover the wall where the radiator was, so the kitchen's heat may need to move. These are the three usual ways to heat a kitchen.
Radiator
Kitchens with a clear stretch of wall
- Heats a room faster than underfloor heating
- Simple to replace or move
- Tall, narrow vertical radiators fit kitchens short of wall space
- Takes wall space that units could use
- Cannot be boxed in: a grille cuts output by about 3 to 5%, a cabinet by much more
- Keep units and large furniture at least 20 cm away
Plinth heater
Kitchens with no free wall for a radiator
- Hides in the plinth under a base unit, leaving the walls free
- A plumbed model runs off the central heating, with a small fan using 18 to 35 W
- An all-electric model needs no pipework
- The fan can be heard, and the grille at floor level must be kept clear
- Needs a plinth at least 120 mm high, or 80 mm for a slim model
- Output drops with cooler water: one model gives about 1.3 kW at 80°C but 0.5 kW at 40°C
Underfloor heating
A floor that is being dug up or rebuilt anyway
- Frees the walls completely
- Wet systems run at about 35 to 55°C, which suits heat pumps
- Electric mats add little height to the floor
- Wet pipes in screed add about 55 to 60 mm before insulation, so retrofitting is disruptive
- A screed floor takes two to three hours to warm up
- Pipes and mats are not laid under fixed units, and electric systems cost more to run
In shortA radiator suits a kitchen with free wall. Where units fill the walls, a plinth heater fits into the plinth, and underfloor heating suits a floor that is being rebuilt anyway.
Ducted or recirculating extraction?
A cooker hood either sends steam and smells outside through a duct, or cleans the air with filters and returns it to the room.
Ducted (extraction)
Kitchens with a short route to an outside wall
- Takes steam, smoke and smells out of the house
- Counts as kitchen extract ventilation, with a minimum rate of 30 litres per second
- Moves more air, with no charcoal filters to keep buying
- Needs a duct route to outside, which not every kitchen has
- Rigid duct is preferred; flexible duct is kept to final connections of 1.5 m or less
- With an open-flued gas appliance in the kitchen, extraction is limited to 20 litres per second
Recirculating (filtration)
Kitchens where no duct can reach outside
- Fits almost anywhere, with no ducting
- Lower cost up front
- Puts some heat and moisture back into the kitchen and moves less air
- Charcoal filters need replacing, from every few months to about once a year
- Does not count as ventilation on its own; the rules then set 60 litres per second for a fan to outside
In shortIf a duct can reach an outside wall, a ducted hood clears more steam and counts as ventilation. A recirculating hood suits kitchens with no duct route, usually alongside a separate extractor fan.
Gas, ceramic or induction?
Gas heats with a flame, ceramic heats the glass, and induction makes heat in the pan itself. Each needs a different supply and a different installer.
Gas
Cooks who like a flame and are keeping a gas supply
- Cheaper to run at present, because gas costs less than electricity
- Tends to spread heat evenly for frying
- New gas hobs have had to include a flame failure device since 2010, which cuts the gas if the flame goes out
- Takes about 12.4 minutes on average to boil a large pan in tests
- Roughly half as energy efficient as induction
- Fiddly to clean, and must be fitted by a Gas Safe registered engineer
Ceramic
Electric cooking with a flat, easy-wipe top
- Flat glass that wipes clean easily
- Boils a large pan in about 7.6 minutes on average
- Most have child locks on the controls
- The glass stays hot for a while after switching off
- Tends to spread heat less evenly than gas
- Usually wired in by an electrician rather than plugged in
Induction
Quick, efficient cooking where the electrical supply allows it
- Boils a large pan in about 4.6 minutes on average
- Highly efficient, because the heat is made in the pan base
- The surface does not heat up without a pan, and the flat glass is easy to clean
- Needs pans with iron in the base; aluminium pans will not work
- Switching from gas usually means capping the gas and adding a dedicated circuit
- Can interfere with pacemakers, so check with your doctor first
In shortIf you are keeping gas, a gas hob avoids new wiring. If you are going electric, induction is quicker and more efficient than ceramic but needs suitable pans and supply.
Integrated or freestanding appliances?
Integrated appliances hide behind doors that match your units. Freestanding ones stand on their own, or slide under the worktop with their own front showing.
Integrated
An unbroken run of matching doors
- Hidden behind furniture doors and flush with the units
- Integrated washing machines clean and rinse on a par with freestanding ones in tests
- Cost more on average, and cost more to install
- Fewer models to choose from
- Less space: integrated fridge freezers held at most 10 shopping bags in tests, against up to 23 for freestanding
- A replacement must match, for example the same fridge to freezer split, and the old door should be kept
Freestanding
A wider choice of models for the money
- More models to choose from
- On a tight budget, more features and faster spin speeds for washing machines
- Simpler to install and to swap later
- On show, and not built to carry a cupboard door
- Fridge freezers need about 5 cm of space at the sides and back
- American-style fridge freezers are about 90 cm wide, can stick out past 60 cm units and cost about 49% more to run
In shortIntegrated suits you if a uniform run of doors matters more than choice and storage. Freestanding gives more choice for the money and is easier to replace later.
Who is allowed to do what
Some kitchen jobs are limited by law to registered or licensed people, and some equipment belongs to someone else. This list is for England; Wales differs in places.
| What | Detail | Who |
|---|---|---|
| Gas hob, cooker, boiler and gas pipes | The law says anyone working on gas must be competent, and businesses must be on the approved register, Gas Safe Register. You can check an engineer's ID card number on the register. | A Gas Safe registered engineer |
| New electrical circuits and consumer units | In England these are notifiable, for example a new cooker circuit. A registered electrician can self-certify the work, so you do not apply to building control yourself. | A registered electrician, or building control |
| Other electrical work in the kitchen | Adding a socket to an existing kitchen circuit is not notifiable in England, but it must still meet the wiring standard and be certificated. In Wales, kitchens count as special locations, so more kitchen work is notifiable. | A competent electrician |
| Replacement windows and back doors | These must meet the Building Regulations. An installer registered with a competent person scheme can sign them off; otherwise building control approves the work. | A registered installer, or building control |
| Knocking through or removing a chimney breast | All structural alterations need Building Regulations approval. A structural engineer or surveyor can check whether a wall is load-bearing and design the beam. | Building control, with an engineer's or surveyor's design |
| Work on a party wall | Cutting into a shared wall for a beam or to remove a chimney breast needs notice at least two months ahead. Drilling for wall units, sockets and replastering normally do not. | You serve notice on the neighbour; surveyors settle any dispute |
| Gas, electricity and water meters | Only your energy supplier, or the network operator, can move a gas or electricity meter, and moving one yourself is illegal. Get your water company's consent before work that moves a water meter, so it can inspect and re-seal it. | Your energy supplier or network operator; your water company |
| Asbestos in older homes | Homes built or refurbished before 2000 may contain asbestos, so tell the trades about any you know of. Sprayed coatings, pipe lagging and asbestos insulating board should only be removed by an HSE-licensed contractor. | An HSE-licensed contractor for the higher-risk materials |
The paperwork to expect
These papers prove the work was done properly and signed off. You may be asked for them when you sell or remortgage, so keep them together.
| What | Detail | Who |
|---|---|---|
| Gas work compliance certificate | For notifiable gas work, such as a new boiler, you must be given a Building Regulations compliance certificate within 30 days. It usually comes through the engineer's registration scheme. | The Gas Safe registered business, through Gas Safe Register |
| Boiler commissioning checklist | This record shows a boiler was installed and commissioned correctly, and logs each service. It is now kept digitally, and the boiler should be registered with its maker within one month. | The engineer who fits the boiler |
| Electrical Installation Certificate | You should get one for new circuits or a new consumer unit. Changes to an existing circuit get a Minor Electrical Installation Works Certificate for each circuit. | The electrician who did the work |
| Electrical compliance certificate | Notifiable electrical work also needs a Building Regulations compliance certificate. The registered electrician arranges it, and it should reach you within 30 days. | The registered electrician's scheme |
| Window and door certificate | Replacement windows and external doors come with a certificate showing a registered installer did the work. It shows up in solicitors' searches when you sell. | The installer's competent person scheme, or building control |
| Building control completion certificate | Structural work, such as a knock-through, is signed off by building control after a completion inspection. It is the evidence the work has Building Regulations approval. | Your building control body |
| Party wall award | If a neighbour does not agree to notified work within 14 days, surveyors settle it with an award. The award is final and binding unless a court changes it. | The party wall surveyor or surveyors |
| Guarantees and manuals | Keep the appliance and worktop guarantees and manuals; some depend on correct fitting or the maker's own sealant. Ask your fitter for the workmanship warranty in writing too. | Appliance and worktop makers, and your fitter |